Smart Array P600 Controller User Guide
Table Of Contents
- HP Smart Array P600 Controller for ProLiant Servers User Guide
- Notice
- Contents
- Hardware features
- Overview of the installation procedure
- Installing the controller hardware
- Updating the firmware
- Configuring an array
- Setting the boot controller and controller order
- Installing device drivers and Management Agents
- Upgrading or replacing controller options
- Replacing, moving, or adding hard drives
- Diagnosing array problems
- Electrostatic discharge
- Regulatory compliance notices
- Acronyms and abbreviations
- Index

Hardware features 6
Temperature range Operating, 10° to 35°C (50° to 95°F); storage, -20° to 55°C (-4° to
131°F)
Relative humidity
(noncondensing)
Operating, 10% to 70%; storage, 5% to 90%
RAID levels supported 0, 1, 1+0, 5, ADG (also called RAID 6)
Connector type Compatible with full-length 3.3-V, 64-bit PCI-X or PCI slot
Transfer rate Up to 1.0 GB/s at 133 MHz (64-bit)
Number of SAS ports 2 (1 internal, and 1 that can be used as internal or external)
SAS transfer rate Up to 1.2 GB/s per port in each direction
For more information about the controller features and specifications, and for information about system
requirements, refer to the HP website (http://www.hp.com/products/smartarray
).