AM312A Smart Array P812/1GB Controller for HP Integrity Servers Installation Guide

For querying/changing Controller mode:
saupdate GET_MODE [ <seg:bus:dev:func> | all | <model> ]
saupdate SET_MODE [ <seg:bus:dev:func> | all | <model> ] [ hba | raid ] [-f]
Error messages
The following error messages might appear when using saupdate:
When keyword LIST or UPDATE is misspelled or extra parameters are specified:
Error: Syntax Error
Usage: saupdate LIST or saupdate UPDATE [ | all ]
When the controller ID in the saupdate UPDATE command is not correct:
No matching controller found
When a firmware file does not exist in the saupdate UPDATE directory:
SANDMAN.BIN does not exist.
File SANDMAN.BIN: Not Found
When an invalid or corrupted firmware file is specified in the saupdate UPDATE command:
SANDMAN.BIN does not exist.
File SANDMAN.BIN: invalid or corrupted
Verifying and updating enclosure firmware offline
Follow the procedures in this section to verify and update the firmware in an external enclosure.
Verifying the enclosure firmware
Use saupdate from the UEFI Shell to verify the firmware image on the enclosure.
To verify the enclosure firmware with saupdate, follow these steps:
1. Prepare to run saupdate from the Offline Diagnostics CD or the UEFI partition:
To run saupdate from the Offline Diagnostic CD:
a. Place the Offline Diagnostic CD containing saupdate.efi in the CD drive before
booting the system.
b. Boot the system to the UEFI Shell prompt.
c. Locate the cdrom entry in the list of mapped devices, and change to the device by
entering its associated fs number (for example, fs0) under UEFI Shell prompt.
d. If the UEFI utility is not located in the root directory, move to the directory where the
file is located, for example:
fs0:\> cd \EFI\HP\TOOLS\IO_CARDS\SmartArray
To run saupdate from the UEFI partition:
a. Download the SA UEFI update utility saupdate.efi and copy it to the UEFI partition.
b. Boot the system to the UEFI Shell and change directories to the UEFI partition.
c. If the UEFI utility is not located in the root directory, move to the directory where the
file is located, for example:
fs0:\> cd \EFI\HP\TOOLS\IO_CARDS\SmartArray
Verifying and updating enclosure firmware offline 15