AM312A Smart Array P812/1GB Controller for HP Integrity Servers Installation Guide
1. Prepare to run saupdate from the Offline Diagnostics CD or the UEFI partition:
• To run saupdate from the Offline Diagnostic CD:
a. Download the firmware and copy it to the UEFI partition.
b. Place the Offline Diagnostic CD containing saupdate.efi in the CD drive before
booting the system.
c. Boot the system to the UEFI Shell prompt.
d. Locate the cdrom entry in the list of mapped devices, and change to the device by
entering its associated fs number (for example, fs0) under UEFI Shell prompt.
e. If the UEFI utility and firmware image files are not located in the root directory, move
to the directory where these files are located, for example:
fs0:\> cd \EFI\HP\TOOLS\IO_CARDS\SmartArray
• To run saupdate from the UEFI partition:
a. Download the Smart Array UEFI update utility saupdate.efi and copy it to the
UEFI partition.
b. Download the firmware and copy it to the UEFI partition.
c. Boot the system to the UEFI Shell and change directories to the UEFI partition.
IMPORTANT: The firmware image file and saupdate.efi must be located in the same
directory. If they are not, copy them to the UEFI partition and run the saupdate from there.
18 Hardware installation