2. Use saupdate UPDATE to update the firmware on the controller:
To update a single enclosure, use this command:
saupdate UPDATE <seg:bus:dev:func:encl_index> <firmware_file>
In the following example, the SAS expander at segment 1, bus C7, device 0, function 0,
index 4 is updated with the firmware file 0507.bin, and the enclosure at 1:C7:0:0:2
is updated with the firmware file CAMSPR0052_6G_app_4MB_ai.pmc:
fs1:\> saupdate update 1:C7:0:0:4 0507.bin
********************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.09.10.02
(C) Copyright 2009 Hewlett-Packard Development Company, L.P.
********************************************************************************
Updating Enclosure in Seg: 1, Bus: C7, Dev: 0, Func: 0, Index: 2
................................................................................
................................................................................
................................................................................
................................................................................
........................................
Activating firmware now, this may take several minutes.
Flashing complete. New FW will be loaded when enclosure is reset.
fs1:\> saupdate update 1:C7:0:0:2 CAMSPR0052_6G_app_4MB_ai.pmc
********************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.09.10.02
(C) Copyright 2009 Hewlett-Packard Development Company, L.P.
********************************************************************************
Updating Enclosure in Seg: 1, Bus: C7, Dev: 0, Func: 0, Index: 2
................................................................................
................................................................................
....................................
Activating firmware now, this may take several minutes.
Flashing complete. New FW will be loaded when enclosure is reset.
To update all attached enclosures, use this command:
saupdate UPDATE <seg:bus:dev:func> all_encl <firmware_file>
Verifying the firmware update
1. After updating the firmware, cycle the power on the system and on any external JBODS
connected to the system.
Verifying and updating enclosure firmware offline 19