Background
Each SCSI channel on the RAID160 SA controller supports up to 14 physical disks. Disks can be of the
Ultra320 or the Ultra160 type.
Each physical disk on a SCSI bus must have a unique ID value in the range of 0 to 15 (except ID 7, which is
typically reserved for controller use). This value is set automatically on hot-pluggable disk drives in the
storage systems that are supported by the RAID160 SA controller.
Do not terminate the disk drives. HP servers and internal cabling provide the required termination of the
SCSI bus.
Do not use disk drives of different capacity in the same array. The excess capacity of larger disk drives
cannot be used by the array and is wasted.
Do not use hot-pluggable disk drives on the same SCSI bus as non-hot-pluggable disk drives.