HP A7143A RAID160 SA Controller Support Guide, February 2007
Installing the RAID160 SA Controller
RAID160 SA Controller OL* Error Recovery
Chapter 4
42
Figure 4-3 SCSI Cable Reconnect Note
At this point you reset the RAID160 SA controller and the online replacement is complete.
If the error message in Figure 4-4 appears, before the online replacement procedure is completed, proceed to
the next section “OL* Error Recovery”.
OL* Error Recovery
If the SCSI cables are disconnected from, or connected to, a controller after the PCI slot is powered off, the
OLAR procedure will fail and the following message will appear (see Figure 4-4, “First Error Message,”):
Figure 4-4 First Error Message
At this point the controller is suspended and will remain suspended, unless the following steps are followed:
1. Click “OK” on the first error message (see Figure 4-4, “First Error Message,”)
2. The following message will appear (see Figure 4-5, “Second Error Message,”).
Figure 4-5 Second Error Message
3. Now, disconnect the SCSI cable(s) from the controller and click “YES”. The following message will
be appear (see Figure 4-6, “SCSI Cable Reconnect Note,”):