HP A7143A RAID160 SA Controller Support Guide, February 2007

Installing the RAID160 SA Controller
Physical Disk Firmware
Chapter 4
60
An example of the lengthy sautil <device_file> command output is provided in ā€œThe sautil Commandā€ on
page 80 in the Troubleshooting chapter.
Issuing the sautil <device_file> -s command provides an abbreviated listing of information for the
RAID160 SA controller and all connected devices including a SCSI Device Summary that lists the SCSI
channel and the SCSI ID for each of the physical disks attached to the RAID160 SA controller. The firmware
version currently installed on each physical disk is also included in the output of the
sautil <device_file> -s command:
# sautil /dev/ciss6 -s
******************************************************************************
**** ****
**** S A U T I L S u p p o r t U t i l i t y ****
**** ****
**** for the HP A7143A RAID160 SA SCSI Adapter ****
**** ****
**** version A.01.01 ****
**** ****
**** (c) Copyright 2003 Hewlett-Packard Development Company, L.P. ****
******************************************************************************
---- DRIVER INFORMATION ------------------------------------------------------
Driver State........................ READY
---- ADAPTER INFORMATION -----------------------------------------------------
Adapter............................. HP A7143A RAID160 SA SCSI Adapter
Hardware Path....................... 0/6/0/0
Serial Number....................... P2313ADDAOVCDK
Device File......................... /dev/ciss6
Hardware Revision................... ’A’
Firmware Revision (in ROM).......... 2.92
# of Logical Drives................. 1
# of Physical Disks Configured...... 4
# of Physical Disks Detected........ 4