HP A7143A RAID160 SA Controller Support Guide, February 2007

Troubleshooting
The sautil Command
Chapter 6
91
sautil <device_file> accept_media_xchg <logical_drive_number>
The sautil <device_file> accept_media_xchg <logical_drive_number> command instructs the
RAID160 SA controller to:
1. Set the state of the specified failed logical drive, <logical_drive_number>, to "OK"
2. Set the states of all failed physical disks that have been replaced via hot-plug exchanges to "OK"
WARNING This option preserves the RAID configuration, logical drive configurations, and
controller settings. If more disks failed than the RAID level is able to accommodate,
data on the failed logical drive may have been compromised. If data has been
compromised you will need to restore from backup media.
In the following example, logical drive “0” accepts a media exchange:
# sautil /dev/ciss6 accept_media_xchg 0
******************************************************************************
**** ****
**** S A U T I L S u p p o r t U t i l i t y ****
**** ****
**** for the HP A7143A RAID160 SA SCSI Adapter ****
**** ****
**** version A.01.01 ****
**** ****
**** (c) Copyright 2003 Hewlett-Packard Development Company, L.P. ****
******************************************************************************
---- DRIVER INFORMATION ------------------------------------------------------
Driver State........................ READY
---- ADAPTER INFORMATION -----------------------------------------------------
Adapter............................. HP A7143A RAID160 SA SCSI Adapter
Hardware Path....................... 0/6/2/0
Device File......................... /dev/ciss6
---- ACCEPT MEDIA EXCHANGE ---------------------------------------------------