HP Smart Array 6400 Series Controllers Support Guide, September 2007

******************************************************************************
---- DRIVER INFORMATION ------------------------------------------------------
Driver State........................ READY
---- CONTROLLER INFORMATION --------------------------------------------------
Controller Product Number........... A9891A
Controller Product Name............. HP PCI-X SmartArray 6404 (Ch A1, A2)
Hardware Path....................... 0/3/1/0/4/0
Device File......................... /dev/ciss4
---- FIRMWARE DOWNLOAD -------------------------------------------------------
** You are downloading the firmware image "CYBORG226.BIN"
** to the controller "/dev/ciss4".
Retrieving firmware image file from disk................... [Done]
Validating the file's signature and size................... [Done]
Retrieving the firmware revision string from ROM........... [Done]
Retrieving the firmware revision string from the file...... [Done]
Current Revision (in ROM)....... 1.92
New Revision (in file).......... 2.26
WARNING: All I/O to this controller will be temporarily halted
while the firmware is being updated.
Are you sure you want to continue (y/n)? y
Preparing for download (this could take up to 2 minutes)... [Done]
Sending the new firmware to the controller................. [Done]
Activating the new firmware................................ [Done]
Resetting the controller (this could take up to 2 minutes). [Done]
Retrieving the firmware revision string from ROM........... [Done]
Current Revision (in ROM)....... 2.26
FIRMWARE DOWNLOAD WAS SUCCESSFUL!
Reminder: The A9891A HP PCI-X SmartArray 6404 is actually two
2-channel controllers sharing one PCI-X connector. Each
2-channel controller has its own firmware. Be sure to
update the firmware on the other 2-channel controller also.
Here are the RAID SA device files (/dev/cissX) found
using "/usr/sbin/ioscan -kfnd ciss":
Class I H/W Path Driver S/W State H/W Type Description
========================================================================
ext_bus 4 0/3/1/0/4/0 ciss CLAIMED INTERFACE PCI-X SmartArray 6404 RAID Controller
/dev/ciss4
ext_bus 7 0/3/1/0/5/0 ciss CLAIMED INTERFACE PCI-X SmartArray 6404 RAID Controller
/dev/ciss7
ext_bus 6 0/5/1/0/4/0 ciss CLAIMED INTERFACE PCI-X SmartArray 6402 RAID Controller
/dev/ciss6
******************************************************************************
**** End of SAUTIL Output ****
******************************************************************************
Physical Disk Firmware
Use the sautil command to confirm and update the firmware version on each of the physical
disks in the SmartArray disk enclosure attached to the Smart Array Controller.
NOTE: This section of the HP Smart Array 6400 Series Controller Support Guide focuses on
the sautil command options that are used to confirm, or change, physical disk firmware. The
other sautil command options listed in the sautil help screen and detailed in the sautil
manpages, are explained in “The sautil Command” (page 56).
You must log in as a superuser to run the sautil command.
36 Installing Smart Array 6400 Series Controllers