HP Smart Array P700m Controller for Integrity Servers Installation Guide, Second Edition
Percentage completed: 100%
Activating firmware now, this may take several minutes.
Resetting and reinitializing controller.
Retrieving firmware version, this may take several minutes.
Current controller firmware version is 6.60 Build 0
Verifying the firmware update
To verify that the firmware update was successful, follow these steps:
1. After updating the firmware, cycle the power on the system and on any external JBODS
connected to the system.
2. Use saupdate LIST to confirm that the correct firmware version is installed. See “Verifying
the controller firmware” (page 5).
HELP or ?
Use HELP or ? to display usage text, program version number, and build date:
Enter: saupdate HELP
or
saupdate ?
Error messages
The following error messages might appear when using saupdate:
• When keyword LIST or UPDATE is misspelled or extra parameters are specified:
Error: Syntax Error
Usage: saupdate LIST or saupdate UPDATE [ | all ]
• When the controller ID in the saupdate UPDATE command is not correct:
No matching controller found
• When a firmware file does not exist in the saupdate UPDATE directory:
INCPTR.BIN does not exist.
File INCPTR.BIN: Not Found
• When an invalid or corrupted firmware file is specified in the saupdate UPDATE command:
INCPTR.BIN does not exist.
File INCPTR.BIN: invalid or corrupted
Verifying the installation
After the system reboots, verify that the installation was successful by following these steps:
1. Enter the swlist command:
# swlist
If the Smart Array Controller is installed correctly, the generated output looks similar to the
following examples:
For HP-UX 11i v3:
RAID-01 B.11.31.0903.01 RAID SA; Supptd HW=A7143A/A9890A/A9891A
For HP-UX 11i v2:
RAID-01 B.11.23.0806 RAID SA; Supptd HW=A7143A/A9890A/A9891A
The version string that appears indicates the version of the RAID-01 bundle installed on
your server.
8 HP-UX installation