HP Smart Array P800 Controller for Integrity Servers Installation Guide, December 2007
Verifying and Updating Controller Firmware Offline
Follow the procedures in this section to verify that the correct adapter firmware version is installed
before you boot the server. Firmware version requirements are found in the HP Smart Array
RAID Controllers Support Matrix at:
http://docs.hp.com/en/netcom.html
WARNING! HP Smart Array P800 Controllers have specific adapter firmware version
requirements for use in HP Integrity servers. Follow the steps in this section to ensure that the
correct firmware version is installed.
Verifying the Controller Firmware
Use saupdate from the EFI Shell to verify the firmware image on the controller.
To verify the controller firmware with saupdate, follow these steps:
1. Prepare to run saupdate from the Offline Diagnostics CD or the EFI partition:
• To run saupdate from the Offline Diagnostic CD:
a. Place the Offline Diagnostic CD containing saupdate.efi in the CD drive before
booting the system.
b. Boot the system to the EFI Shell prompt.
c. Locate the cdrom entry in the list of mapped devices, and change to the device by
entering its associated fs number (for example, fs0) under EFI Shell prompt.
d. If the EFI utility is not located in the root directory, move to the directory where
the file is located, for example:
fs0:\>cd \EFI\HP\TOOLS\IO_CARDS\SmartArray
• To run saupdate from the EFI partition:
a. Download the Smart Array EFI update utility saupdate.efi and copy it to the
EFI partition.
b. Boot the system to the EFI Shell and change directories to the EFI partition.
c. If the EFI utility is not in the root directory, move to the directory where the file is
located, for example:
fs0:\>cd \EFI\HP\TOOLS\IO_CARDS\SmartArray
2. Use saupdate LIST to display all detected Smart Array controllers and the active firmware
versions. For example:
fs0:\EFI\TOOLS> saupdate list
********************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.06.10.03
(C) Copyright 2006 Hewlett-Packard Development Company, L.P.
********************************************************************************
Seg Bus Dev Func Description Version
0 52 0 0 HP Smart Array P400 2.08
In this example, the system contains one Smart Array P400 Controller at segment 0, bus 52,
device 0, function 0, running firmware version 2.08.
Verifying and Updating Controller Firmware Offline 11