HP Smart Array P800 Controller for Integrity Servers Installation Guide, December 2007

2. Use saupdate LIST to confirm that the correct firmware version is installed. See “Verifying
the Controller Firmware” (page 11).
For example:
fs0:\EFI\TOOLS> saupdate list
************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.07.09.02
(C) Copyright 2006 Hewlett-Packard Development Company, L.P.
************************************************************************
Seg Bus Dev Func Description Version
0 8 0 0 HP Smart Array P800 4.10
External Enclosures Connected :
Index Description Version
2 MSA70 2.06
HELP or ?
Use HELP or ? to display usage text, program version number, and build date:
Enter: saupdate HELP
or
saupdate ?
Verifying the Installation
After the system reboots, verify that the installation was successful by following these steps:
1. Enter the swlist command:
# swlist
If the Smart Array Controller is installed correctly, the generated output looks similar to the
following examples:
For HP-UX 11i v3:
RAID-01 B.11.31.0709.01 RAID SA; Supptd HW=A7143A/A9890A/A9891A
For HP-UX 11i v2:
RAID-01 B.11.23.0706 RAID SA; Supptd HW=A7143A/A9890A/A9891A
The version string that appears indicates the version of the RAID-01 bundle installed on
your server.
2. Enter the ioscan -kfnd ciss command:
# ioscan -kfnd ciss
If the Smart Array Controller software is installed correctly, the generated output looks
similar to this:
# ioscan -kfnd ciss
Class I H/W Path Driver S/W State H/W Type Description
==========================================================================
ext_bus 5 0/6/0/0/0/0/1/0/0/0 ciss CLAIMED INTERFACE PCIe SAS SmartArray P400 RAID Controller
/dev/ciss5
If the software is not installed correctly, reinstall it using swinstall. See “Installing
Software” (page 8).
Verifying the Installation 17