HP Smart Array P800 Controller for Integrity Servers Installation Guide, December 2007

3. Boot the system to the EFI Shell and change directories to the EFI partition.
When you are ready, use saupdate UPDATE to update the firmware on the controller.
To update a single enclosure, use this command:
saupdate UPDATE <seg:bus:dev:func:encl_index> <firmware_file>
To update all attached enclosures, use this command:
saupdate UPDATE <seg:bus:dev:func> all_encl <firmware_file>
For example, to update the enclosure at segment 0, bus 8, device 0, function 0, index 2 with the
firmware file VWG2_206.S3:
fs0:\EFI\TOOLS> saupdate UPDATE 0:8:0:0:2 VWG2_206.S3
************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.07.09.02
(C) Copyright 2006 Hewlett-Packard Development Company, L.P.
************************************************************************
Updating Enclosure in Seg: 0, Bus: 8, Dev: 0, Func: 0, Index: 2
Sending Image Chunk No: 117 of 117
Activating firmware now, this may take several minutes.
Retrieving firmware version, this may take several minutes.
Current Enclosure Firmware version is 2.06
Verifying the Firmware Update
After updating the firmware, cycle the power on the system and on any external JBODS connected
to the system.
Use saupdate LIST to confirm that the correct firmware version is installed; see “Verifying
the Controller Firmware” (page 11). For example:
fs0:\EFI\TOOLS> saupdate list
************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.07.09.02
(C) Copyright 2006 Hewlett-Packard Development Company, L.P.
************************************************************************
Seg Bus Dev Func Description Version
0 8 0 0 HP Smart Array P800 4.10
External Enclosures Connected :
Index Description Version
2 MSA70 2.06
HELP or ?
Use HELP or ? to display usage text, program version number, and build date:
Enter: saupdate HELP
or
saupdate ?