RAID-01 (ciss) B.11.31.1005 Mass Storage Driver Release Notes, Edition 2 (August 2010)

Table 5 HP-UX 11i v3 March 2010 fixes RAID-01 B.11.31.1003 (continued)
DescriptionSR Number
The sautil utility does not check the battery count when a RAID 6 (ADG) volume is
created.
QXCR1000941269
The sautil utility cannot clear the disk error and firmware error logs.
QXCR1000963505
Table 6 HP-UX 11i v3 September 2009 fixes RAID-01 B.11.31.0909
DescriptionSR Number
Performing a health check of unloaded drivers causes a system panic.QXCR1000921599
In sautil command output, the card identification for Smart Array P700m and P800 are
interchanged.
QXCR1000960290
There were no defects or fixes included in RAID-01 version B.11.31.0906.
Table 7 HP-UX 11i v3 March 2009 fixes RAID-01 B.11.31.0903
DescriptionSR Number
The sautil utility does not display interrupt statistics when using the stat option.
QXCR1000875017
There were no defects or fixes included in RAID-01 version B.11.31.0809.
4 Known problems and limitations
This section provides a list of problems and limitations known to HP when these release notes
were published. If workarounds are available, they are included.
4.1 For all Smart Array controllers
A newly-created logical volume might not be available.
When you create a new logical volume on a Smart Array controller, you must run the ioscan
command to make the volume available for use.
Unnecessary reboot occurs when removing the ciss driver.
If you use the swremove command to remove the dynamically loaded ciss driver, the
Critical Resource Analysis (CRA) can fail. This causes swremove to incorrectly reboot the
system.
Severity: Low
Corrective Action: To avoid this CRA failure, before running swremove install patch
PHCO_36356 (or a superseding patch). Patches are available from the HP IT Resource Center
at:
http://itrc.hp.com/
Under “Maintenance and Support,” click the Patch Database link, then search for the patch
number. For more information on how to manage and install patches, see the Patch
Management User Guide for HP-UX 11.x Systems at:
http://www.hp.com/go/hpux-core-docs
NOTE: If you remove the dynamically loaded ciss driver while it is in use, or if you remove
the statically loaded ciss driver at any time, you must perform a reboot. This is normal
behavior under these conditions, and is not affected by patch PHCO_36356.
Automatic hot-plug is not detected.
The HP Smart Array Controllers do not automatically detect the hot-plug of internal disks.
6