RAID-01 (ciss) B.11.31.
© Copyright 2010 Hewlett-Packard Development Company, L.P. Legal Notices Hewlett-Packard makes no warranty of any kind with regard to this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Confidential computer software.
This document provides updated information about the December 2010 release of the RAID-01 bundle for HP-UX 11i v3. Changes from Edition 1 “New features” (page 4) provides updated instructions on finding information about supported tape devices.
Table 3 Minimum supported RAID-01 (ciss) versions for HP-UX 11i v3, by adapter Adapter Minimum driver version A7143A, A9890A, A9891A B.11.31 Smart Array P400 B.11.31.0709.01 Smart Array P410i B.11.31.1005 Smart Array P411 B.11.31.1005 Smart Array P700m B.11.31.0903 Smart Array P800 B.11.31.0712 Smart Array P812 B.11.31.1005 2 New and changed features in this release 2.
Table 6 HP-UX 11i v3 May 2010 fixes — RAID-01 B.11.31.1005 SR Number Description QXCR1000964181 The sautil and saconfig utilities are enhanced to support Smart Array Advanced Pack. QXCR1001002955 Disk firmware download fails on P410i. QXCR1001007900 HBA firmware revision is not updated in driver structures. QXCR1001007903 32bit DMA handles need to be converted to 64bit. QXCR1001018760 Firmware update of MDS600 fails, yet it displays new firmware.
Severity: Low Corrective Action: To avoid this CRA failure, before running swremove install patch PHCO_36356 (or a superseding patch). Patches are available from the HP IT Resource Center at http://itrc.hp.com/. Under “Maintenance and Support,” click the Patch Database link, then search for the patch number. For more information on how to manage and install patches, see the Patch Management User Guide for HP-UX 11.x Systems at http://www.hp.com/go/hpux-core-docs.
B.11.31.0906. Performing a clean installation of AR0909 on a server with an MSA2300 Series enclosure connected will cause a system panic. To perform a clean installation of AR0909 on a server with an MSA2300 Series enclosure, follow these steps: 1. 2. 3. 4. 5. 6. Power off the system. Disconnect the MSA2300 Series enclosure. Power on the system. Install HP-UX 11i v3, Application Release 0909. Install RAID-01 B.11.31.0909. Connect the MSA2300 Series enclosure.
Corrective Action: Reconnect the cables or reinsert the disks, then reset the Smart Array controller using the sautil reset_ctlr command. After the controller is reset, ioscan correctly reports the status of the disks as CLAIMED. • Disconnected external storage enclosures are not properly detected by ioscan. If you disconnect all cables connecting a Smart Array controller to external storage enclosures, saconfig and sautil show the status of the logical drives as FAILED.
6 Related information The latest documentation for RAID-01 is available in English at http://www.hp.com/go/ hpux-iocards-docs. 7 Software availability in native languages The RAID-01 product is available only in the English language.