RAID-01 (ciss) B.11.31.1012 mass storage driver release notes

Table 6 HP-UX 11i v3 May 2010 fixes RAID-01 B.11.31.1005
DescriptionSR Number
The sautil and saconfig utilities are enhanced to support Smart Array Advanced Pack.QXCR1000964181
Disk firmware download fails on P410i.QXCR1001002955
HBA firmware revision is not updated in driver structures.QXCR1001007900
32bit DMA handles need to be converted to 64bit.QXCR1001007903
Firmware update of MDS600 fails, yet it displays new firmware.QXCR1001018760
HP-UX ciss driver has to operate in a single mode (either RAID or HBA).QXCR1001022493
The sautil and saconfig utilities are enhanced to reflect HBA mode, version info, etc.QXCR1001023834
Table 7 HP-UX 11i v3 March 2010 Fixes RAID-01 B.11.31.1003
DescriptionSR Number
I/O hangs occur under heavy load.QXCR1000863084
MSI-X interrupts are not assigned with HBA locality taken into consideration.QXCR1000914639
The ciss driver does not support the GET_SCSI_DISK_BINDING ioctl.QXCR1000934272
The ciss driver causes a panic in rare circumstances on systems with very low memory.QXCR1000934287
The sautil utility does not check the battery count when a RAID 6 (ADG) volume is created.QXCR1000941269
The sautil utility cannot clear the disk error and firmware error logs.QXCR1000963505
Table 8 HP-UX 11i v3 September 2009 fixes RAID-01 B.11.31.0909
DescriptionSR Number
Performing a health check of unloaded drivers causes a system panic.QXCR1000921599
In sautil command output, the card identification for Smart Array P700m and P800 are
interchanged.
QXCR1000960290
There were no defects or fixes included in RAID-01 version B.11.31.0906.
Table 9 HP-UX 11i v3 March 2009 fixes RAID-01 B.11.31.0903
DescriptionSR Number
The sautil utility does not display interrupt statistics when using the stat option.QXCR1000875017
There were no defects or fixes included in RAID-01 version B.11.31.0809.
4 Known problems and limitations
This section provides a list of problems and limitations known to HP when these release notes were
published. If workarounds are available, they are included.
4.1 For all Smart Array controllers
A newly-created logical volume might not be available.
When you create a new logical volume on a Smart Array controller, you must run the ioscan
command to make the volume available for use.
Unnecessary reboot occurs when removing the ciss driver.
If you use the swremove command to remove the dynamically loaded ciss driver, the Critical
Resource Analysis (CRA) can fail. This causes swremove to incorrectly reboot the system.
4 Known problems and limitations 5