RAID-01 (ciss) B.11.31.1109 Mass Storage Driver Release Notes, edition 2 HP-UX 11i v3 Abstract This document provides information about the September 2011 release of the RAID-01 bundle for HP-UX 11i v3.
© Copyright 2011 Hewlett-Packard Development Company, L.P. Legal Notices Hewlett-Packard makes no warranty of any kind with regard to this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Confidential computer software.
This document provides updated information about the September 2011 release of the RAID-01 bundle for HP-UX 11i v3. Changes since edition 1 The following features are new with this version of B.11.31.1111. • Smart Array P711m is added to “Supported controllers” (page 3). • Smart Array P711m is added to “Minimum supported RAID-01 (ciss) versions for HP-UX 11i v3, by adapter” (page 4).
1.1 Driver versions This section lists the minimum supported RAID-01 ciss driver version for each Smart Array host bus adapter. Table 3 Minimum supported RAID-01 (ciss) versions for HP-UX 11i v3, by adapter Adapter Minimum driver version A7143A, A9890A, A9891A B.11.31 Smart Array P400 B.11.31.0709.01 Smart Array P410i B.11.31.1005 Smart Array P411 B.11.31.1005 Smart Array P700m B.11.31.0903 Smart Array P711m B.11.31.1109 Smart Array P800 B.11.31.0712 Smart Array P812 B.11.31.
Problems fixed in recent versions Table 5 HP-UX 11i v3 December 2010 Fixes — RAID-01 B.11.31.1012 SR number Description QXCR1001070560 Support for tape partial reads when different read/write block sizes are used. QXCR1001073598 The saconfig /dev/cissX –N command displays no output. QXCR1001047583 PHY error threshold message displays an incorrect connector number for MSA2000sa G2 enclosures. QXCR1001057381 Online firmware update of D2600 and D2700 enclosures to version 0102 fails.
4.2 For SAS (Serial-Attached SCSI) Smart Array controllers • SATA disks are not supported when the controller is in HBA mode. • New Smart Array P700m controller installations should be on HP-UX 11i v3 March 2010 release or later. If you are considering a new installation of an HP Smart Array P700m Controller, HP recommends that you configure it on HP-UX 11i v3 March 2010 release or later. New installation of a P700m controller is not recommended on HP-UX 11i v3 releases prior to March 2010.
Corrective Action: Reconnect the cables or reinsert the disks, then reset the Smart Array controller using the sautil reset_ctlr command. After the controller is reset, ioscan correctly reports the status of the disks as CLAIMED. • Disconnected external storage enclosures are not properly detected by ioscan. If you disconnect all cables connecting a Smart Array controller to external storage enclosures, saconfig and sautil show the status of the logical drives as FAILED.
6 Related information The latest documentation for RAID-01 is available in English at http://www.hp.com/go/ smart-array-raid-docs. 7 Software availability in native languages The RAID-01 product is available only in the English language.