RAID-01 (ciss) B.11.31.1109 Mass Storage Driver Release Notes, edition 2
1.1 Driver versions
This section lists the minimum supported RAID-01 ciss driver version for each Smart Array host
bus adapter.
Table 3 Minimum supported RAID-01 (ciss) versions for HP-UX 11i v3, by adapter
Minimum driver versionAdapter
B.11.31A7143A, A9890A, A9891A
B.11.31.0709.01Smart Array P400
B.11.31.1005Smart Array P410i
B.11.31.1005Smart Array P411
B.11.31.0903Smart Array P700m
B.11.31.1109Smart Array P711m
B.11.31.0712Smart Array P800
B.11.31.1005Smart Array P812
2 New and changed features in this release
2.1 New features
The following feature is new with this version of RAID-01:
• Support is added for Smart Array P711m controller.
Version B.11.31.1109 of the RAID-01 bundle supports the Smart Array P711m controller.
For details on supported servers, use the Smart Array support matrix.
• Smart Array utilities now support larger drives.
The saconfig and sautil utilities are enhanced to support logical drives larger than 2 TB
(QXCR1001104360).
2.2 Changed features
The following features are changed with this version of RAID-01:
• The sautil utility is enhanced.
The sautil utility has been enhanced as follows:
◦ The command output now displays the LUN WWID (QXCR1001104101).
◦ The sautil vpd command now displays the controller mode (QXCR1001084442).
3 Problems fixed in this version
Table 4 HP-UX 11i v3 September 2011 fixes — RAID-01 B.11.31.1109
DescriptionSR number
On cards controlled by the ciss driver, the ANSI version is overwritten with an incorrect
lower value.
QXCR1001119028
The scsimgr replace_wwid command fails on ciss devices.QXCR1001095075