RAID-01 (ciss) B.11.31.1109 Mass Storage Driver Release Notes, edition 2
Problems fixed in recent versions
Table 5 HP-UX 11i v3 December 2010 Fixes — RAID-01 B.11.31.1012
DescriptionSR number
Support for tape partial reads when different read/write block sizes are used.QXCR1001070560
The saconfig /dev/cissX –N command displays no output.QXCR1001073598
PHY error threshold message displays an incorrect connector number for MSA2000sa G2
enclosures.
QXCR1001047583
Online firmware update of D2600 and D2700 enclosures to version 0102 fails.QXCR1001057381
The saconfig command doesn't create logical drives of the size in specified with the -c
option.
QXCR1001063275
Table 6 HP-UX 11i v3 September 2010 fixes — RAID-01 B.11.31.1009
DescriptionSR Number
On HP Integrity BL8x0c i2 servers, sautil(1M) does not clearly identify internal discs in non-RAID
setting.
QXCR1001040695
4 Known problems and limitations
This section provides a list of problems and limitations known to HP when these release notes were
published. If workarounds are available, they are included.
4.1 For all Smart Array controllers
• A newly-created logical volume might not be available.
When you create a new logical volume on a Smart Array controller, you must run the ioscan
command to make the volume available for use.
• Unnecessary reboot occurs when removing the ciss driver.
If you use the swremove command to remove the dynamically loaded ciss driver, the Critical
Resource Analysis (CRA) can fail. This causes swremove to incorrectly reboot the system.
Severity: Low
Corrective Action: To avoid this CRA failure, before running swremove install patch
PHCO_36356 (or a superseding patch). Patches are available from the HP IT Resource Center
at http://itrc.hp.com/.
Under “Maintenance and Support,” click the Patch Database link, then search for the patch
number. For more information on how to manage and install patches, see the Patch
Management User Guide for HP-UX 11.x Systems at http://www.hp.com/go/hpux-core-docs.
NOTE: If you remove the dynamically loaded ciss driver while it is in use, or if you remove
the statically loaded ciss driver at any time, you must perform a reboot. This is normal
behavior under these conditions, and is not affected by patch PHCO_36356.
• Automatic hot-plug is not detected.
The HP Smart Array Controllers do not automatically detect the hot-plug of internal disks.
Corrective Action: After replacing a physical disk, run the sautil command with the scan
option.
4 Known problems and limitations 5