RAID-01 (ciss) B.11.31.1203 Mass Storage Driver Release Notes HP-UX 11i v3 Abstract This document contains specific information that is intended for users of this HP product.
© Copyright 2012 Hewlett-Packard Development Company, L.P. Legal Notices Hewlett-Packard makes no warranty of any kind with regard to this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Confidential computer software.
This document provides information about the March 2012 release of the RAID-01 bundle for HP-UX 11i v3. 1 RAID-01 overview The RAID-01 bundle in HP-UX Application Release 1203 contains version B.11.31.
Table 3 Minimum supported RAID-01 (ciss) versions for HP-UX 11i v3, by adapter (continued) Adapter Minimum driver version Smart Array P410i B.11.31.1005 Smart Array P411 B.11.31.1005 Smart Array P700m B.11.31.0903 Smart Array P711m B.11.31.1109 Smart Array P800 B.11.31.0712 Smart Array P812 B.11.31.1005 2 New and changed features in this release 2.1 New features The following features are new with this version of RAID-01: • Logical drives can now be created on physical disks larger than 2 TB.
4.1 For all Smart Array controllers • A newly-created logical volume might not be available. When you create a new logical volume on a Smart Array controller, you must run the ioscan command to make the volume available for use. • Unnecessary reboot occurs when removing the ciss driver. If you use the swremove command to remove the dynamically loaded ciss driver, the Critical Resource Analysis (CRA) can fail. This causes swremove to incorrectly reboot the system.
For more information, see the HP Smart Array SAS Controllers for Integrity Servers Support Guide at http://www.hp.com/go/smart-array-raid-docs. • HP-UX installation fails. Installation of HP-UX 11i v3 fails when installing to an array of eight 146 GB SAS disks configured as a single RAID 0 logical volume. Corrective Actions: ◦ Option 1: Install patch PHCO_36555. Patches are available from the HP IT Resource Center, at: http://itrc.hp.
5.1 Required software • OS Platform and Version Compatibility Before installing the Smart Array Controller software, install a supported HP-UX Operating System. To determine the supported HP-UX versions for your system, see the HP Smart Array RAID Controllers Support Matrix at http://www.hp.com/go/smart-array-raid-docs. • Locating Software for the Smart Array Controllers The HP-UX driver and utilities are not shipped with the controller, but are available through Software Depot at: http://www.hp.