RAID-01 (ciss) B.11.31.1303.01 Mass Storage Driver Release Notes HP-UX 11i v3 Abstract This document contains specific information that is intended for users of this HP product.
© Copyright 2012, 2013 Hewlett-Packard Development Company, L.P. Legal Notices Hewlett-Packard makes no warranty of any kind with regard to this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Confidential computer software.
Contents RAID-01 overview.....................................................................................................................4 Driver versions.....................................................................................................................4 New and changed features in this release...................................................................................5 New features.................................................................................................
This document provides information about the March 2013 release of the RAID-01 bundle for HP-UX 11i v3. RAID-01 overview The RAID-01 bundle in HP-UX Application Release 1303 contains version B.11.31.1303.
Table 3 Minimum supported RAID-01 (ciss) versions for HP-UX 11i v3, by adapter (continued) Adapter Minimum driver version Smart Array P410i B.11.31.1005 Smart Array P411 B.11.31.1005 Smart Array P700m B.11.31.0903 Smart Array P711m B.11.31.1109 Smart Array P800 B.11.31.0712 Smart Array P812 B.11.31.1005 New and changed features in this release New features The following features are new with this version of RAID-01: • There are no new features with this release.
Table 7 HP-UX 11i v3 March 2012 fixes — RAID-01 B.11.31.1203 SR number Description QXCR1001147832 New CPU ID is not propagated to mass storage stack after an interrupt migration. QXCR1001152548 Firmware failures occur with D2200sb enclosures. QXCR1001154483 The ciss driver does not notify ESCSI stack with ESCSI_TP_OFFLINE event. QXCR1001159876 The sautil(1M) utility shows the mode as RAID instead of HBA when the HBA is in the offline state.
For SAS (Serial-Attached SCSI) Smart Array controllers • SATA disks are not supported when the controller is in HBA mode. • New Smart Array P700m controller installations should be on HP-UX 11i v3 March 2010 release or later. If you are considering a new installation of an HP Smart Array P700m Controller, HP recommends that you configure it on HP-UX 11i v3 March 2010 release or later. New installation of a P700m controller is not recommended on HP-UX 11i v3 releases prior to March 2010.
Corrective Action: Reconnect the cables or reinsert the disks, then reset the Smart Array controller using the sautil reset_ctlr command. After the controller is reset, ioscan correctly reports the status of the disks as CLAIMED. • Disconnected external storage enclosures are not properly detected by ioscan. If you disconnect all cables connecting a Smart Array controller to external storage enclosures, saconfig and sautil show the status of the logical drives as FAILED.
Related information The latest documentation for RAID-01 is available in English at http://www.hp.com/go/ smart-array-raid-docs. Software availability in native languages The RAID-01 product is available only in the English language. Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hp.com).