RAID-01 (ciss) B.11.31.1303.01 Mass Storage Driver Release Notes HP-UX 11i v3, edition 1
Table 3 Minimum supported RAID-01 (ciss) versions for HP-UX 11i v3, by adapter (continued)
Minimum driver versionAdapter
B.11.31.1005Smart Array P410i
B.11.31.1005Smart Array P411
B.11.31.0903Smart Array P700m
B.11.31.1109Smart Array P711m
B.11.31.0712Smart Array P800
B.11.31.1005Smart Array P812
New and changed features in this release
New features
The following features are new with this version of RAID-01:
• There are no new features with this release.
Changed features
The following features are changed with this version of RAID-01:
• There are no changed features with this release.
Problems fixed in this version
Table 4 HP-UX 11i v3 March 2013 fixes — RAID-01 B.11.31.1303.01
DescriptionSR number
RAID expansion to 0 GB is printing ambiguous messageQXCR1001227954
Creation or migration to RAID 50 or 60 on P800 should fail with proper messageQXCR1001230100
Problems fixed in recent versions
Table 5 HP-UX 11i v3 September 2012 fixes — RAID-01 B.11.31.1209.01
DescriptionSR number
RAID Stripe size migration fails if logical drive is in “Interim recovery” modeQXCR1001189384
saconfig fails to use full size of high capacity disks into smaller size volumesQXCR1001204295
Updated saconfig(1M) manpage for some correctionsQXCR1001206785
saconfig prints wrong capacity in failure message for huge unsupported user specified
capacity
QXCR1001211777
RAID volume creation with zero size capacity does not FAILQXCR1001227770
Table 6 HP-UX 11i v3 March 2012 fixes — RAID-01 B.11.31.1203.01
DescriptionSR number
P2000 IO Hang recovery takes long time in rare scenariosQXCR1001194782
New and changed features in this release 5