RAID-01 (ciss) B.11.31.1403 Mass Storage Driver Release Notes HP-UX 11i v3 Abstract This document contains specific information that is intended for users of this HP product.
© Copyright 2012, 2013, 2014 Hewlett-Packard Development Company, L.P. Legal Notices Hewlett-Packard makes no warranty of any kind with regard to this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Confidential computer software.
This document provides information about the March 2014 release of the RAID-01 bundle for HP-UX 11i v3. 1 RAID-01 overview The RAID-01 bundle in HP-UX Fusion Release 1403 contains version B.11.31.
Table 3 Minimum supported RAID-01 (ciss) versions for HP-UX 11i v3, by adapter (continued) Adapter Minimum driver version Smart Array P411 B.11.31.1005 Smart Array P700m B.11.31.0903 Smart Array P711m B.11.31.1109 Smart Array P800 B.11.31.0712 Smart Array P812 B.11.31.1005 2 New and changed features in this release 2.1 New features The following features are new with this version of RAID-01: • There are no new features with this release. 2.
Table 6 HP-UX 11i v3 September 2012 fixes — RAID-01 B.11.31.1209.01 (continued) SR number Description QXCR1001206785 Updated saconfig(1M) manpage for some corrections QXCR1001211777 saconfig prints wrong capacity in failure message for huge unsupported user specified capacity QXCR1001227770 RAID volume creation with zero size capacity does not FAIL Table 7 HP-UX 11i v3 March 2012 fixes — RAID-01 B.11.31.1203.
NOTE: If you remove the dynamically loaded ciss driver while it is in use, or if you remove the statically loaded ciss driver at any time, you must perform a reboot. This is normal behavior under these conditions, and is not affected by patch PHCO_36356. • Automatic hot-plug is not detected. The HP Smart Array Controllers do not automatically detect the hot-plug of internal disks. Corrective Action: After replacing a physical disk, run the sautil command with the scan option. 4.
4.3 For parallel SCSI Smart Array controllers • Partially disconnected disks and external cables are not properly detected by ioscan. If you remove all but one cable connecting external storage enclosures, or if you remove physical disks that are part of a logical drive from the enclosures, saconfig and sautil show the status of the logical drive as FAILED. However, ioscan reports the status of the disks incorrectly.
5.4 Other requirements • HP Support Tools Manager (STM) and Event Monitoring Service (EMS) You must use STM vD.01.00 or later and EMS vA.04.20 or later for support with Smart Array controllers. • HP-UX Virtual Partitions (vPars) You must install vPars vA.05.05 or later to use Smart Array Controllers in a vPars environment. 6 Related information The latest documentation for RAID-01 is available in English at http://www.hp.com/go/ smart-array-raid-docs.