Table 6 HP-UX 11i v3 September 2012 fixes RAID-01 B.11.31.1209.01 (continued)
DescriptionSR number
Updated saconfig(1M) manpage for some correctionsQXCR1001206785
saconfig prints wrong capacity in failure message for huge unsupported user specified
capacity
QXCR1001211777
RAID volume creation with zero size capacity does not FAILQXCR1001227770
Table 7 HP-UX 11i v3 March 2012 fixes RAID-01 B.11.31.1203.01
DescriptionSR number
P2000 IO Hang recovery takes long time in rare scenariosQXCR1001194782
Table 8 HP-UX 11i v3 March 2012 fixes RAID-01 B.11.31.1203
DescriptionSR number
Diagnostic message filtering is added to the ciss driver.QXCR1001146707
New CPU ID is not propagated to mass storage stack after an interrupt migration.QXCR1001147832
Firmware failures occur with D2200sb enclosures.QXCR1001152548
The ciss driver does not notify ESCSI stack with ESCSI_TP_OFFLINE event.QXCR1001154483
The sautil(1M) utility shows the mode as RAID instead of HBA when the HBA is in the
offline state.
QXCR1001159876
Additional statistics are needed in sautil(1M).QXCR1001181576
Table 9 HP-UX 11i v3 September 2011 fixes RAID-01 B.11.31.1109
DescriptionSR number
On cards controlled by the ciss driver, the ANSI version is overwritten with an incorrect
lower value.
QXCR1001119028
The scsimgr replace_wwid command fails on ciss devices.QXCR1001095075
4 Known problems and limitations
This section provides a list of problems and limitations known to HP when these release notes were
published. If workarounds are available, they are included.
4.1 For all Smart Array controllers
A newly-created logical volume might not be available.
When you create a new logical volume on a Smart Array controller, you must run the ioscan
command to make the volume available for use.
Unnecessary reboot occurs when removing the ciss driver.
If you use the swremove command to remove the dynamically loaded ciss driver, the Critical
Resource Analysis (CRA) can fail. This causes swremove to incorrectly reboot the system.
Severity: Low
Corrective Action: To avoid this CRA failure, before running swremove install patch
PHCO_36356 (or a superseding patch). Patches are available from the HP IT Resource Center
at http://itrc.hp.com/.
Under “Maintenance and Support, click the Patch Database link, then search for the patch
number. For more information on how to manage and install patches, see the Patch
Management User Guide for HP-UX 11.x Systems at http://www.hp.com/go/hpux-core-docs.