HP StorageWorks MSL Library Extender user guide (AQ746-96005, September 2009)

Table Of Contents
SolutionCauseMessageCode
Power cycle both Libraries.
Run the Library Extender
cycle test.
See Table 8, page 50.
Library Extender has reported
an error condition.
BD
Download the current lib-
rary extender firmware
bundle to update the Librar-
ies to compatible firmware
versions.
Retry the operation.
The Extender is incompatible
with the Libraries, or the firm-
ware versions on the Libraries
and Extender are incompatible
with each other. See Table
9, page 52.
Extender or library stack incom-
patibility.
BE
Table 6 Sub-codes for error B8
MessageSub-code
Library Extender expected40
Lower Library expected41
Master Library expected42
Table 7 Sub-codes for error B9
MessageSub-code
No device present31
I²C write error32
I²C read error33
Table 8 Sub-codes for error BD
SolutionCauseMessageSub-code
Power cycle the master
Library.
Run the Library Extender
cycle test.
Retry the operation.
The Extender robotic cannot
locate its home position within
the master Library.
Sensor master home not found.01
Power cycle the lower Lib-
rary.
Run the Library Extender
cycle test.
Retry the operation.
The Extender robotic cannot
locate its home position within
the lower Library.
Sensor lower home not found.02
Using diagnostic tools and troubleshooting50