SmartStart 8.70 Release Notes

Customer advisories 23
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
01806612):
Red Hat Enterprise Linux 4 Update 8 Linux may panic during installation of SNMP Agents/PSP
Version 8.26/8.30 on ProLiant Server with NC326i Integrated Dual Port PCI Express Gigabit Server
Adapter using igb Network Driver included in distribution. For detailed information, click the following
link
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
01879545):
ProLiant BL685 G6 Server Blade HP NC-Series Broadcom 10GbE Multifunction Driver for Windows
Server 2003 Version 4.8.101.0 (or earlier) causes blue screen if the server is configured with or
upgraded to four 8400-series processors. For detailed information, click the following link
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
01763051):
ProLiant DL320 G6 and ProLiant ML330 G6 Servers System stops responding on startup or shutdown
if the server is configured with 4 GB (or more) of memory, a Smart Array B110i SATA RAID Controller,
and Windows Server 2003 (32-Bit). For detailed information, click the following link
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
01763044):
Driver update required: ProLiant Servers and Smart Array B110i SATA RAID Controller A driver
update is required to avoid loss of RAID 1 protection for a two-drive boot volume after installing
hpahcisr driver RPM version 1.2.0-14 under Red Hat Enterprise Linux 5. For detailed information, click
the following link
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
01763049):
ProLiant Servers and Smart Array Controllers HP ProLiant Array Configuration Utility for Windows
Version 8.25 (or earlier) may not function under Internet Explorer 8. For detailed information, click the
following link
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
01763057):
ProLiant Servers and Smart Array P212/P410/P411 Controllers Controller may stop responding
under NetWare 6.5 while booting in Maintenance Mode, unloading the HPQCISS driver, or
performing a drive array expansion, deletion, or erase using CPQONLIN. For detailed information,
click the following link
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
01759097):
HP ProLiant ML 350 G6 and ProLiant ML370 G6 Servers - Integrated Lights-Out May Not Function and
Boot Delay May Occur if Smart Array P212, P410, or P411 is Installed in PCI-Express Slot 1 on Servers
Built Before April 8, 2009. For detailed information, click the following link:
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
01736985)
HP BladeSystem Mezzanine HBAs - Server May Experience a Blue Screen if Drivers for the Emulex and
QLogic HBAs on the SmartStart or ProLiant Support Pack 8.10 or 8.15 CD Are Used With HP BL Emulex
and QLogic Mezzanine Host Bus Adapters. For detailed information, click on the following link:
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c0
1772203)
HP Smart Array E200 Or HP Smart Array E200i Firmware Version 1.80 (or earlier) - FIRMWARE
UPGRADE RECOMMENDED for ProLiant Servers Running Windows Server 2003 To Prevent A Blue