HP B-series 16Gb FC Switches Hardware Reference Guide

4. Assemble the outer rails as follows:
NOTE: For switches with Port Side Air Intake, attach Left outer rail to the right side of the
rack and Right outer rail to the left side of the rack.
a. Attach the left outer rail and right outer rail to the rear mounting brackets using two 1/4-20
hex with captive star lock washers attached loosely, as shown in Figure 11 (page 27).
Do not tighten the nuts.
Figure 11 Installing the outer rails (HP 10000 Series Rack)
b. Depending on the rack you are using, complete one of the following tasks:
For an HP 10000 Series Rack, install two #10-32 x 1/2-inch Phillips panhead screws
with captive star lock washers and two #10 adapter washers in the upper and lower
holes on the right rail. Then, install two #10-32 x 1/2-inch Phillips panhead screws
with captive star lock washers and two #10 adapter washers in the upper and lower
holes on the left rail. See Figure 12 (page 27).
Figure 12 Assembling the outer rails (HP 10000 Series Rack)
Installing the switch 27