Brocade Fabric OS v7.2.1 Release Notes v1.0 December 13, 2013 Document History Document Title Summary of Changes Publication Date Brocade Fabric OS v7.2.1 Release Notes v1.
© 2013 Brocade Communications Systems, Inc. All Rights Reserved. ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, and Vyatta are registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their respective owners.
Contents Overview ...................................................................................................................................................... 5 Additional Hardware Platform Support ................................................................................................................... 5 New Features & Support .........................................................................................................................................
WebTools ................................................................................................................................................................ 29 Zoning ..................................................................................................................................................................... 29 Miscellaneous .....................................................................................................................................................
Overview Fabric OS (FOS) v7.2.1 is a maintenance release based on FOS v7.2.0. All hardware platforms and features supported in FOS v7.2.0 are also supported in FOS v7.2.1. This release also contains fixes for many defects including those from the FOS v7.2.0a and b patch releases. In addition to the fixes noted above and listed in the defect tables at the end of this document, FOS v7.2.1 also includes support for additional hardware platforms and enhanced capabilities.
Optionally Licensed Software Fabric OS v7.2 includes all basic switch and fabric support software, as well as optionally licensed software that is enabled via license keys. Optionally licensed features include: Brocade Ports on Demand—Allows customers to instantly scale the fabric by provisioning additional ports via license key upgrade. (Applies to select models of switches).
Adaptive Networking with QoS—Adaptive Networking provides a rich framework of capability allowing a user to ensure high priority connections obtain the bandwidth necessary for optimum performance, even in congested environments. The QoS SID/DID Prioritization and Ingress Rate Limiting features are the first components of this license option, and are fully available on all 8Gb and 16Gb platforms. Note : With FOS v7.
10GbE FCIP/10G Fibre Channel – This license enables the two 10GbE ports on the FX8-24 and/or the 10G FC capability on FC16-xx blade ports supported on DCX 8510 platforms. On the Brocade 6510, Brocade 6520 this license enables 10G FC ports.
Temporary License Support The following licenses are available in FOS v7.
Supported Switches FOS v7.2.1 supports the following existing platforms: 300, 5100, 5300, 7800, VA-40FC, Brocade Encryption Switch, DCX, DCX-4S 6505, 6510, 6520, DCX 8510-8, DCX 8510-4 FC16-32, FC16-48, FC8-32E, FC8-48E, FX8-24, FS8-18 on DCX 8510-8/DCX 8510-4 FC8-16, FC8-32, FC8-48, FC8-64, FX8-24, FS8-18, FCOE10-24 on DCX/DCX-4S 5410, 5424, 5430, 5450, 5480, 5470, 5460, NC-5480 Support merged to FOS v7.2.
Switch operating system version Error numbers and messages received supportSave command output and associated files o For dual CP platforms running FOS v6.
FOS Migration Considerations This section contains important details to consider before migrating to or from this FOS release. FOS Upgrade and Downgrade Special Considerations DCX/DCX-4S units running any FOS v7.1.x or FOS v7.2.0x can be non-disruptively upgraded to FOS v7.2.1. This upgrade is non-disruptive to both FC and FCoE traffic (when using FCOE10-24 blades). Any firmware activation on Brocade 7800, or DCX, DCX-4S, DCX 8510-8, DCX 8510-4 with FX8-24 will disrupt I/O traffic on the FCIP links.
Important Notes This section contains information that you should consider before you use this Fabric OS release. Brocade Network Advisor Compatibility Brocade Network Advisor greatly simplifies the steps involved in daily operations while improving the performance and reliability of the overall SAN and IP networking environment. Brocade Network Advisor unifies, under a single platform, network management for SAN, LAN and converged networks.
SMI Compatibility It is important to note that host SMI-S agents cannot be used to manage switches running FOS v7.2. If users want to manage a switch running FOS v7.2 using SMI-S interface, they must use Brocade Network Advisor’s integrated SMI agent. Fabric OS Compatibility The following table lists the earliest versions of Brocade software supported in this release, that is, the earliest supported software versions that interoperate.
Multi-Protocol Router Interoperability Brocade 7500 and FR4-18i blade V6.2.2 and higher 4 6 8 McDATA SANRouters 1620 and 2640 Not Supported NOS (VDX Platform) Interoperability Brocade VDX6710, VDX6720, VDX6730 NOS v2.1.1 or later7 Brocade VDX8770 NOS 3.0 or later Table Notes: 1 When routing to an M-EOS edge fabric using frame redirection, the M-EOS fabric must have a FOS-based product in order to configure the frame redirection zone information in the edge fabric.
SNMP Support Starting with FOS v7.2.0, the Fabric OS MIB Reference document is not updated. You can obtain the latest MIBs from the downloads area of MyBrocade site after logging in. For information about SNMP support in Fabric Operating System (FOS) and how to use MIBs, see the Fabric OS Administrator’s Guide. Obtaining the MIBs You can download the MIB files required for this release from the downloads area of the MyBrocade site.
Fabric OS v7.2 software is fully qualified and supports the blades for the DCX/DCX-4S noted in the following table: DCX/DCX-4S Blade Support Matrix 16-, 32-, 48- and 64-port 8Gbit port blades (FC8-16, FC8-32, FC8-48, FC8-64) Supported with FOS v6.0 and above (FC8-64 requires FOS v6.4) with any mix and up to 8/4 of each. No restrictions around intermix. FC10-6 Not supported on FOS v7.1 or later Intelligent blade Up to a total of 8/4 intelligent blades.
Fabric OS v7.2 software is fully qualified and supports the blades for the DCX 8510-8 and DCX 8510-4 noted in the table below. DCX 8510-8/DCX 8510-4 Blade Support Matrix FC16-32, FC16-48 16G FC blades FOS v7.0 or later. FC8-64 64 port 8Gbit port blade With any mix and up to 8/4 of each. No restrictions around intermix. Note: FC8-16, FC8-32, FC8-48 blades are not supported on DCX 8510 platforms. FC8-32E, FC8-48E FOS v7.0.1 or later. Intelligent blade Up to a total of 8/4 intelligent blades.
Power Supply Requirements for Blades in DCX/DCX-4S Blades Type of Blade FC10-61, FC816, FC8-32, FC 8-48, FC864 Port Blade FR4-18i1 FS8-18, FX8-24, FCOE10-24 DCX/DCX-4S DCX/DCX-4S @110 VAC (Redundant configurations) @200-240 VAC (Redundant configurations) 2 Power Supplies 2 Power Supplies Intelligent Blade Not Supported 2 Power Supplies Intelligent Blade Not Supported DCX: 2 or 4 Power Supplies Comments DCX-4S: 2 Power Supplies Distribute the Power Supplies evenly to 2 different AC con
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Type of Blade DCX 8510-8 @110 VAC (Redundant configurations) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments Any combination of 8Gb or 16Gb ports with QSFP ICLs FC8-64, FC16-32, FC8-32E Port Blade 4 Power Supplie
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Type of Blade DCX 8510-8 @110 VAC (Redundant configurations) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments 384 16Gb ports + QSFP ICLs FC16-32, FC16-48 Port Blade Not Supported 4 Power Supplies 200-240VAC: For
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-4 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-4 Backbone Hardware Reference Manual) Configured Blades Number of Ports Type of Blade DCX 8510-4 @110 VAC (Redundant configurations) DCX 8510-4 @200-240 VAC (Redundant configurations) Comments 96 ports max with QSFP ICLs FC16-32, FC8-32E Port Blade 2 Power Supplies 2 Power Supplies 1+1 redunda
If FOS v7.2 or later is factory installed (or net installed), Adaptive Networking features are always available. This matches the behavior of the Brocade 6520 and all products shipping with prior versions of FOS and with the Adaptive Networking license factory installed. Ports will come up in AE mode by default If the remote port supports QOS and is not explicitly disabled, the link will come up in QOS mode. Otherwise, the link will come up in normal mode.
Gen 5 platforms and blades are capable of setting an EHT value on an individual port basis. On 8G platforms EHT is set on an ASIC-wide basis, meaning all ports on a common ASIC will have the same EHT setting. Extra care should be given when configuring EHT on 8G platforms or Gen 5 platforms with 8G blades to ensure E_Ports are configured with an appropriate Hold Time setting. When using Virtual Fabrics and creating a new Logical Switch when running FOS v7.1.
With Windows and Veritas Volume Manager/Veritas Dynamic Multipathing, when LUN sizes less than 400MB are presented to BES for encryption, a host panic may occur and this configuration is not supported in the FOS v6.3.1 or later release. Hot Code Load from FOS v7.1.x to FOS v7.2 or later is supported. Cryptographic operations and I/O will be disrupted but other layer 2 FC traffic will not be disrupted.
FCoE/DCB/CEE (FCOE10-24) When upgrading a DCX/DCX-4S with one or more FCOE10-24 blades from FOS v6.x to FOS v7.0.0 or later, the user should carefully review Chapter 5 of the FOS v7.0.0 Converged Enhanced Ethernet Administrator’s Guide. Ethernet L2 traffic with xSTP Hello timer set to less than or equal to 3 seconds may experience momentary traffic disruption during HA failover. Hot plugging a CP with firmware level less than FOS v6.3.
are identical this merge logic guarantees uniqueness in any modified login group name (switches with the same OUI will have unique last 3 bytes in WWN). However, if the participating switches have different OUIs but identical last three bytes in the switch WWNs, then the merge logic will fail to guarantee uniqueness of login group names. This will result in one of the login groups being dropped from the configuration.
FL_Port (Loop) Support FL_Port is not supported on FC16-32, FC16-48, FC8-32E, FC8-48E, Brocade 6510, Brocade 6505 and Brocade 6520. The FC8-48 and FC8-64 blade support attachment of loop devices. Virtual Fabrics must be enabled on the chassis and loop devices may only be attached to ports on a 48-port or 64-port blade assigned to a non-Default Logical Switch operating with the default 10bit addressing mode (they may not be in the default Logical Switch).
However, a port may remain in “Port Throttled” state for an extended period of time and may never come online if it fails to negotiate speed successfully with the neighboring port. Users are advised to check the speed setting of the neighboring switch port to determine the cause of the speed negotiation failure. Example Output: 74 9 10 Throttled) 36ed40 id N8 In_Sync FC Disabled (Port Port Mirroring Port Mirroring is not supported on the Brocade 7800.
“aa.bb.cc.dd.ee.ff.gg.hh” when associated with a zone alias will be stored as “aa.bb.cc.dd.ee.ff.gg.hh” on a switch operating with FOS v6.2.0 or later. This behavioral change in saved zone alias WWN members will not impact most environments. However, in a scenario where a switch with a zone alias WWN member with upper case characters (saved on the switch with pre-FOS v6.2.
It is recommended that for directors with more than 300 E_Ports, the switch be disabled prior to executing the “switchCfgTrunk” command (used to disable or enable trunking on the switch). During non-disruptive firmware upgrades, E_Ports in R-RDY mode may cause some frame drops on the E-port links. The Brocade Network Advisor seed switch should always have the highest FOS version used in the fabric.
Defects Closed with Code Change in Fabric OS v7.2.1 This sections lists the defects with Critical, High, and Medium Technical Severity closed with a code change as of December 13, 2013 in Fabric OS v7.2.1. Note: these defects are formatted with an updated defect table structure applying to all future, previously unpublished defects. Defect ID: DEFECT000415126 Technical Severity: High Probability: High Product: FOS Technology: Management Reported In Release: FOS7.1.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000454580 Technical Severity: Medium Probability: Low Product: FOS Technology: Security Reported In Release: FOS6.4.2 Technology Area: Fabric Authentication FOS7.2.1(Fixed) Closed In Release(s): Symptom: With SSL configured on Active CP, a newly inserted Standby CP may panic and go through an unnecessary additional reboot.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000461699 Technical Severity: High Probability: Low Product: FOS Technology: Security Reported In Release: FOS7.1.0 Technology Area: Encryption FOS7.2.1(Fixed) Closed In Release(s): Symptom: CVLC might crash during host login to VT or crypto configuration change. Condition: Issue will only be seen on Brocade Encryption Switch or FS8-18 blade.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000466240 Technical Severity: Medium Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.1.0 Technology Area: NTP - Network Time Protocol FOS7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000468458 Technical Severity: High Probability: Low Product: FOS Technology: Traffic Management Reported In Release: FOS7.2.0 Technology Area: FC-FC routing FOS7.2.1(Fixed) Closed In Release(s): Symptom: FCR may indicate the error message "switch not ready for ex-ports" in switchshow.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000473752 Technical Severity: Medium Probability: Low Product: FOS Technology: Management Reported In Release: FOS7.1.1 Technology Area: CLI FOS7.2.1(Fixed) Closed In Release(s): Symptom: portaddress --show command when executed from Default Switch will display the details of the ports present in other logical switches too. Condition: Applicable only for VF enabled switches with no impact to the functionality.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000475035 Technical Severity: Medium Probability: Medium Product: FOS Technology: Security Reported In Release: FOS7.0.2 Technology Area: Encryption FOS7.2.1(Fixed) Closed In Release(s): Symptom: BES becomes non-responsive and host paths are lost after BES replacement. Condition: Issue will be seen only in BES/FS8-18 after execution of “cryptocfg –replace” command on the group leader.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000477854 Technical Severity: High Probability: Low Product: FOS Technology: Traffic Management Reported In Release: FOS7.0.2 Technology Area: ICLs - Inter-chassis Links FOS7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000481199 Technical Severity: Medium Probability: Medium Product: FOS Technology: Management Reported In Release: FOS7.2.0 Technology Area: Web Tools FOS7.2.1(Fixed) Closed In Release(s): Symptom: Web Tools will be blocked while launching from Network Advisor 12.0.4 or lower version. Condition: On launching Web Tools from Network Advisor 12.0.4. Workaround: Launch the Web Tools from the web browser.
Closed with Code Change in Fabric OS v7.2.1 Note: the following defects have been previously published and are formatted with the previous defect table structure. Defect ID: DEFECT000361971 Technical Severity: High Summary: i2c port reset on Brocade 8G SFPs Symptom: F-Port was logged out of switch due to laser fault during to media access. Risk of Fix: Low Probability: Low Feature: System Controls/EM Function: PCI/I2C Reported In Release: FOS7.0.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000453711 Technical Severity: Medium Summary: Certificate key is not deleted when the certificate is deleted from Non-Default switch using seccertutil command. Symptom: Standby CP/switch may continuously reboot with error message such as "SSLCertificateFile: file ‘/etc/fabos/certs/sw0/xxx.crt’ does not exist or is empty on console".
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000464907 Technical Severity: High Summary: Misbehaving device cause switch to panic Symptom: During a period of time, device sends switch non-stop 0 sized ELS frames. These 0 sized frames were not properly checked and freed, and eventually the switch panics after running of memory. Risk of Fix: Low Probability: Low Feature: FOS Software Function: Panic / OOM Reported In Release: FOS6.1.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000467589 Technical Severity: Medium Summary: snmpconfig does not show community 1 during configuration on v7.1.1 Symptom: User cannot configure "community 1" with snmpconfig --set command Risk of Fix: Medium Probability: Medium FOS Software Feature: Function: SNMP Reported In Release: FOS7.1.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000468413 Technical Severity: High Summary: firmwaredownload -s on standby CP produces protocol failure in circuit setup messages on the console Symptom: Firmware download on the standby CP takes a long time to reach Y/N prompt and several "poll: protocol failure in circuit setup" console messages resulted. Risk of Fix: High Probability: Low Feature: Striker/Spike Platform Services Function: VEX Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000470185 Technical Severity: High Summary: portcfgfillword's passive option does not work Symptom: The passive option in portCfgFillWord does not work. When issuing: "portcfgfillword 3 passive". The fillword immediately takes effect on the port, regardless of port speed. Risk of Fix: High Probability: Medium Feature: 8G ASIC Driver Function: C2 ASIC driver Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000472367 Technical Severity: High Summary: An EX-Port goes into Mod_Invalid state after a switch disable/enable of a core backbone switch Symptom: When a user performs a switch disable/enable, one of the EX-Ports can go into the Mod_Invalid state with Speed Mismatch/Incompatible sfp reason Risk of Fix: Low Probability: Low 16G Platform Services Feature: Function: FOS Kernel Drivers Reported In Release: FOS7.2.
Closed with Code Change in Fabric OS v7.2.
Closed with Code Change in Fabric OS v7.2.1 Defect ID: DEFECT000474717 Technical Severity: High Summary: FICON Disk warm start processing causes inoperative CHPIDs through an XRC emulation enabled FCIP Tunnel Symptom: FICON Error: IOS001E devAddr,INOPERATIVE PATH on CHPID after the disck controller warm start was initiated. Workaround: Disable all FICON emulation features on the FCIP Tunnels that provide access to the Disk Subsystem.