Defect ID:
DEFECT000475264
Technical Severity:
High
Probability:
Medium
Product:
FOS
Technology:
Security
Reported In Release:
FOS7.1.1
Technology Area:
Fabric Authentication
Closed In Release(s):
FOS7.2.1a(Fixed)
Symptom:
After password expiration in switches with multiple logical switches, excessive login failures may
trigger repeated secd panics.
Condition:
This happens when password expires in a setup with large number of logical switches or customer
triggers multiple security violations with very high frequency via scan tools
Workaround:
Disconnect the management Ethernet cable.
Recovery:
Stop security scanning tool and fix any security violation until upgrade to a code release with fix.
Defect ID:
DEFECT000477009
Technical Severity:
Critical
Probability:
Low
Product:
FOS
Technology:
Virtualization
Reported In Release:
FOS7.0.0_pha
Technology Area:
Access Gateway
Closed In Release(s):
FOS7.2.1a(Fixed)
Symptom:
A host connected to a NPIV port on an Access Gateway has multiple virtual clients. Only the
physical HBA is able to login. The virtual client logins are rejected.
Condition:
The issue occurs under the following conditions:
1. F-ports have never bounced since upgrading to a FOS version with the Persistent ALPA feature.
2. The Persistent ALPA feature is enabled for the first time.
3. Virtual clients login without first bouncing the Access Gateway port where the host is connected.
Workaround:
Disable all F-ports on the Access Gateway before trying to login virtual clients.
Recovery:
Disable _all_ the affected F-ports, then enable all the affected ports. To determine which ports are
affected, run this command on all F-ports:
ag --printalpamap <F-port_number>
If the CLI comes back with _Hash Table is empty_, then the port is affected.
Defect ID:
DEFECT000477834
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Distance
Reported In Release:
FOS7.1.0
Technology Area:
OSTP - Open Systems Tape
Pipelining
Closed In Release(s):
FOS7.2.1a(Fixed)
Symptom:
In an FCIP tunnel using OSTP, tape server reports intermittent missing block errors.
Condition:
During error recovery for FC CRC errors, OSTP may incorrectly send frames out of order.
Defect ID:
DEFECT000479882
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
FICON
Reported In Release:
FOS7.1.0
Technology Area:
FICON emulation
Closed In Release(s):
FOS7.2.1a(Fixed)
Symptom:
Host reported IFCCs due to aborted FICON RRS/Device Level Exception/LACK Sequence
Condition:
If a FICON Disk controller returns a device level exception frame to a read record set CCW
command chain, the IFCCs will occur.
Workaround:
Disable XRC Emulation on the FCIP Tunnel