Brocade Fabric OS v7.2.1a Release Notes v1.0

Closed with Code Change in Fabric OS v7.2.1
Fabric OS v7.2.1a Release Notes v1.0 Page 42 of 55
Defect ID:
DEFECT000469507
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Security
Reported In Release:
FOS7.0.1
Technology Area:
Encryption
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
Tape backup jobs on encrypted tape may fail.
Condition:
Issue will be seen on Brocade Encryption Switch or FS8-18 blade with hosts and targets that doesn’t
support SRR/FCP_CONF and tape pipelining is enabled for the tape LUN.
Workaround:
Disable tape pipelining for tape LUNs corresponding to targets/CTC which don’t support
SRR/FCP_CONF.
Defect ID:
DEFECT000473144
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.1.1
Technology Area:
Fabric Watch
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
The "fmmonitor" CLI command is able to change the time base on each filters. However, "thconfig"
CLI command is unable to change the time base of each filters and displays "Timebase not supported
by this class".
Condition:
Always seen while configuring time base for filters using "thconfig".
Workaround:
fmmonitor can be used in place of thconfig for timebase configuration for filter class.
Recovery:
fmmonitor can be used in place of thconfig for timebase configuration for filter class.
Defect ID:
DEFECT000473752
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Management
Reported In Release:
FOS7.1.1
Technology Area:
CLI
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
portaddress --show command when executed from Default Switch will display the details of the ports
present in other logical switches too.
Condition:
Applicable only for VF enabled switches with no impact to the functionality.
Defect ID:
DEFECT000474101
Technical Severity:
Critical
Probability:
Low
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.0.0
Technology Area:
supportShow
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
In a virtual fabric environment, a logical port stuck in an invalid/incomplete state triggered a switch
panic during a switchshow/supportsave
Condition:
On a rare condition, in a VF environment, if a port is not indexed correctly, subsequent data collection
will result in a panic.