Brocade Fabric OS v7.2.1a Release Notes v1.0

Closed with Code Change in Fabric OS v7.2.1
Fabric OS v7.2.1a Release Notes v1.0 Page 43 of 55
Defect ID:
DEFECT000474392
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Security
Reported In Release:
FOS7.1.0
Technology Area:
Encryption
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
In a BES environment with CTC, hosts may lose access to LUNs temporarily.
Condition:
Issue will be seen on Brocade Encryption Switch or FS8-18 blade when BES/FS8-18 acting as an N
port device, aborted the PLOGI in advance.
Defect ID:
DEFECT000474459
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Management
Reported In Release:
FOS7.0.2
Technology Area:
SNMPv2, SNMPv3 & MIBs
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
SNMP test traps are not received with "snmptraps --send" command when the switch is in AG mode.
Condition:
Impact AG switches running FOS version below v7.x.
Defect ID:
DEFECT000474697
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Security
Reported In Release:
FOS7.1.0
Technology Area:
Encryption
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
Host lost access to some paths of LUNs intermittently during encryption change commits.
Condition:
In encryption environment (BES/FS8-18), with higher ITL count configured, hosts configured with
CTC may lose access to some paths of LUNs temporarily while committing the crypto configuration
changes.
Defect ID:
DEFECT000475035
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Security
Reported In Release:
FOS7.0.2
Technology Area:
Encryption
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
BES becomes non-responsive and host paths are lost after BES replacement.
Condition:
Issue will be seen only in BES/FS8-18 after execution of “cryptocfg –replace” command on the group
leader.
Defect ID:
DEFECT000476212
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Security
Reported In Release:
FOS7.0.1
Technology Area:
Encryption
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
Restore from encrypted tape may fail with I/O errors.
Condition:
With more than one initiator configured in a tape container and tape pipelining enabled for the LUN,
a new login from a different host to virtual target may cause the on-going tape restore operation (with
another host) to fail.
Workaround:
Disable tape pipelining for tape LUNs corresponding to targets/CTC where more than one host is
configured.