Brocade Fabric OS v7.0.2e Release Notes v1.0

Defects
Closed with Code Change in Fabric OS v7.0.2e
This section lists the defects with Critical, High, and Medium Technical Severity closed with a code change as
of May 29, 2014 in FOS v7.0.2e.
Defect ID:
DEFECT000361971
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Other
Reported In Release:
FOS7.0.0
Technology Area:
Other
Symptom:
F-Port was logged out of switch due to laser fault during media access.
Condition:
This is an unlikely situation that may be encountered under heavy CPU load and rare timing race
condition. i2c read of smart data has been enhanced to address this for impacted CPU type.
Defect ID:
DEFECT000408703
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Traffic Management
Reported In Release:
FOS6.4.2
Technology Area:
BB Credits
Symptom:
"CRC with Good EOF Errors detected" may cause buffer credit loss.
Condition:
DCX-4S platform with FC8-48 installed in Slot 1; Slot 1 port 2
Recovery:
Manual tuning or auto tuning
Defect ID:
DEFECT000411138
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Other
Reported In Release:
FOS7.0.0
Technology Area:
Other
Symptom:
DCX family could experience a hafailover during core blade failure.
Condition:
In an unlikely event of handling hardware error interrupts on core blade, CP paniced due to race
condition attempting to bring core blade down gracefully.
Defect ID:
DEFECT000417440
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Management
Reported In Release:
FOS7.0.0
Technology Area:
CLI
Symptom:
Detected termination of name server daemon (NSD) during the execution of the CLI command
"nodefind".
Condition:
The CLI command "nodefind" triggers switch panic when name server shows two devices present for
the same WWN.
Workaround:
Do not execute the CLI command "nodefind".
Defect ID:
DEFECT000418392
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Management
Reported In Release:
FOS7.1.0
Technology Area:
Web Tools
Symptom:
Weblinker crash while the fabric is being monitored by Brocade Network Advisor.
Condition:
This may be encountered in a large fabric with security policy activated.