Brocade Fabric OS v7.0.2e Release Notes v1.0

Fabric OS v7.0.2e Release Notes v1.0 Page 35 of 53
Defect ID:
DEFECT000430239
Technical Severity:
High
Probability:
Medium
Product:
FOS
Technology:
Distance
Reported In Release:
FOS7.0.0
Technology Area:
FCIP
Symptom:
FCIP tunnel bounces due to DRAM2 memory allocation failures or BLS-5024 event.
Condition:
Memory allocation failures lead to VE ports down with circuits InProg.
Recovery:
FX8-24 requires reset to recover.
Defect ID:
DEFECT000431101
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Other
Reported In Release:
FOS7.0.0
Technology Area:
Other
Symptom:
When pulling out a disk from a 3rd party vendor storage, access to the whole storage is lost.
Condition:
After hareboot, loop enable bit is not set. If a disk is removed from a loop storage connected to
switch fabric loop (FL) port, then access to storage is lost.
Recovery:
Bounce port by portdisable and portenable
Defect ID:
DEFECT000432406
Technical Severity:
High
Probability:
Medium
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS6.4.2
Technology Area:
Logging
Symptom:
Customer observes multiple supportsave processes on switch without actively initiating a recent
supportsave. These processes consume memory and may lead to switch panic when an additional
supportsave is initiated.
Condition:
Hung supportsave processes left on switch.
Workaround:
Kill stale supportsave PIDs
Recovery:
After switch panic, no further recovery is needed.
Defect ID:
DEFECT000433200
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Management
Reported In Release:
FOS7.0.2
Technology Area:
Web Tools
Symptom:
Under rare condition Weblinker/HTTPD are terminated and restarted but still cannot service the
HTTP requests. All subsequent Webtools/BNA requests encounter the error "Chassis is not ready for
management".
Note:
This fix does not fully resolve this issue but it provides a non-disruptive workaround for the interim
period. With this fix customer may workaround/recover from this condition with hafailover/hareboot,
or may contact support for manual HTTPD restart workaround.
This issue is fully resolved via Defect 477596 fix in FOS 7.0.2e/7.1.1b/v7.1.2/7.2.1.
Condition:
This may be encountered on very rare occasions when switches are managed by Webtools/Brocade
Network Advisor.
Workaround:
NONE without this fix. Use reboot to recover.