Brocade Fabric OS v7.0.2e Release Notes v1.0

Fabric OS v7.0.2e Release Notes v1.0 Page 49 of 53
Defect ID:
DEFECT000441913
Technical Severity:
High
Summary:
A 16Gbit switch may panic when an ICL port enters soft fault state. This is very unlikely but may also
occur with Backend Internal or Backend External port.
Symptom:
During switch install, slot power cycle test, observed 16G switch panic.
Probability:
Medium
Feature:
16G Platform Services
Function:
FOS Kernel Drivers
Reported In Release:
FOS7.0.2
Service Request ID:
1032557
Closed with Code Change in Fabric OS v7.0.2b
This section lists the defects with Critical, High, and Medium Technical Severity closed with a code change as
of March 18, 2013 in FOS v7.0.2b
Defect ID:
DEFECT000428780
Technical Severity:
High
Summary:
When running full bandwidth bi-directional traffic in recommended 16G ICL topology
configuration, some traffic flows may experience a performance throughput degradation.
Symptom:
Observed performance throughput degradation for some ICL traffic flows in a 8 flow ICL
topology
Probability:
Medium
Feature:
16G ASIC driver
Function:
Routing
Reported In Release:
FOS7.0.2
Defect ID:
DEFECT000409897
Technical Severity:
High
Summary:
Switches running FOS v7.0.x firmware may have an issue bringing F ports online when
multiple ports attempt to login to the switch at the same time
Symptom:
F-ports cannot come on line and CLI “switchshow” has the ports as "Disabled (Switch not
ready for F or L ports)”.
Probability:
Medium
Feature:
16G Platform Services
Function:
FOS kernel drivers
Reported In Release:
FOS7.0.2
Defect ID:
DEFECT000358156
Technical Severity:
High
Summary:
FCIP Tunnel bounce caused by chip reset on FX8-24
Symptom:
Chip reset due to PCIe errors with raslog BLS-5023. The chip reset can cause tunnel bounce and
IO halt
Probability:
Low
Feature:
Striker/Spike Platform Services
Function:
Blade Driver
Reported In Release:
FOS7.0.0
Defect ID:
DEFECT000387013
Technical Severity:
Medium
Summary:
Stale AG entry remains present in management server database after the removal of AG.
Symptom:
Switch stays in manageability view even after it is physically removed from fabric.
Probability:
Low
Feature:
FOS Software
Function:
Access Gateway
Reported In Release:
FOS6.2.2
Service Request ID:
699581