Brocade Fabric OS v7.0.2e Release Notes v1.0

Fabric OS v7.0.2e Release Notes v1.0 Page 52 of 53
Defect ID:
DEFECT000423054
Technical Severity:
High
Summary:
Specifying 32 character usernames in snmpconfig causes unexpected termination of snmpd and
rolling reboot
Symptom:
Termination of snmpd occurs, message [KSWD-1002] is displayed.
Workaround:
Specify usernames less than 15 characters in length.
Probability:
High
Feature:
FOS Software
Function:
SNMP
Reported In Release:
FOS6.3.2
Service Request ID:
1092977
Defect ID:
DEFECT000424701
Technical Severity:
Medium
Summary:
portloopbacktest -nframes option does not work correctly
Symptom:
The portloobacktest -nframes option currently sends one frame at a time whereas burst
capabilities are required.
Feature:
Diagnostics
Function:
Other
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000425581
Technical Severity:
High
Summary:
CRC w/ good EOF observed on ports 1/24 and 1/74 on FC8-64 in BR8510
Symptom:
CRC w/ good EOF and enc errors occurring on ports 1/34 and 1/74. FOS auto-tuning cycles
through first 6 tuning value, but then blade is faulted before it can try other settings.
Probability:
Medium
Feature:
FOS Software
Function:
ASIC Driver
Reported In Release:
FOS7.0.2
Service Request ID:
Case#1099691,Case#10
Defect ID:
DEFECT000426728
Technical Severity:
Medium
Summary:
Experiencing CRC w/Good EOF errors C2-5825 on BR48000 port 5/45 with FC8-32 installed in
slot 3
Symptom:
CRC with Good EOF Errors is reported on slot 5/45 when FC8-32 card is installed in slot 3 of a
BR48000 system.
Probability:
Medium
Feature:
FOS Software
Function:
ASIC Driver
Reported In Release:
FOS6.4.3
Service Request ID:
1084752
Defect ID:
DEFECT000427117
Technical Severity:
Medium
Summary:
Frimwaredownload on BR6505 is not blocked from FOSv7.0.2x to FOSv7.0.0x
Symptom:
Brocade 6505 switch is supported with FOS v7.0.1 or above. Loading pre-v7.0.1 firmware will
render 6505 switch inoperable.
Probability:
High
Feature:
FIRMWARE DOWNLOAD
Function:
Firmware Download
Reported In Release:
FOS7.0.2
Service Request ID:
,1110373/1110326
Defect ID:
DEFECT000428368
Technical Severity:
Medium
Summary:
turboramtest output is differenet dependent on switch platform
Symptom:
Inconsistent output from turboramtest on BR8510 and BR6510
Probability:
Low
Feature:
Diagnostics
Function:
Post Diags
Reported In Release:
FOS7.0.2
Service Request ID:
1102971