Brocade Fabric OS MIB Reference v7.1.0 (53-1002750-01, March 2013)

96 Fabric OS MIB Reference
53-1002750-01
fcFeOp group
4
fcFeOp group
This group consists of tables that contain operational status and established service parameters
for the fabric element and the attached Nx_Ports.
Implementation of this group is mandatory.
fcFxPortStackedConnMode
1.3.6.1.3.42.2.1.1.5.1.12
Read only A value indicating the mode of stacked connect supported by the
Fx_Port.
fcFxPortClass2SeqDeliv
1.3.6.1.3.42.2.1.1.5.1.13
Read only A flag indicating whether Class 2 sequential delivery is supported by
the Fx_Port.
Valid values:
yes (1)
no (2)
fcFxPortClass3SeqDeliv
1.3.6.1.3.42.2.1.1.5.1.14
Read only A flag indicating whether Class 3 sequential delivery is supported by
the Fx_Port.
Valid values:
yes (1)
no (2)
fcFxPortHoldTime
1.3.6.1.3.42.2.1.1.5.1.15
Read only The maximum time (in microseconds) that the Fx_Port holds a frame
before discarding the frame if it is unable to deliver the frame. The
value 0 means that the Fx_Port does not support this parameter.
fcFxPortBaudRate
1.3.6.1.3.42.2.1.1.5.1.16
Read only The FC-0 baud rate of the Fx_Port.
The Brocade 12000, 24000, 48000, and DCX directors do not
support this MIB variable.
fcFxPortMedium
1.3.6.1.3.42.2.1.1.5.1.17
Read only The FC-0 medium of the Fx_Port.
fcFxPortTxType
1.3.6.1.3.42.2.1.1.5.1.18
Read only The FC-0 transmitter type of the Fx_Port.
fcFxPortDistance
1.3.6.1.3.42.2.1.1.5.1.19
Read only The FC-0 distance range of the Fx_Port transmitter.
TABLE 33
Object and OID Access Description
TABLE 34
Object and OID Access Description
fcFxPortOperTable
1.3.6.1.3.42.2.1.2.1
Not
accessible
A table that contains one entry for each Fx_Port in the fabric element,
operational status, and parameters of the Fx_Ports.
fcFxPortOperEntry
1.3.6.1.3.42.2.1.2.1.1
Not
accessible
An entry containing operational status and parameters of an Fx_Port.
fcFxPortOperModuleIndex
1.3.6.1.3.42.2.1.2.1.1.1
Read only Identifies the module containing the Fx_Port for which this entry
contains information.
fcFxPortOperFxPortIndex
1.3.6.1.3.42.2.1.2.1.1.2
Read only Identifies the Fx_Port within the module. This number ranges from 1 to
the value of fcFeModulePortCapacity for the associated module. The
value remains constant for the identified Fx_Port until the module is
re-initialized.