Brocade Fabric OS MIB Reference v7.1.0 (53-1002750-01, March 2013)

110 Fabric OS MIB Reference
53-1002750-01
Physical entity group
5
entPhysicalClass
1.3.6.1.2.1.47.1.1.1.1.5
(continued)
Read only Brocade DCX directors can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (eight port blades, two CPs,
four power supplies, three fans)
Module: Eight entries for port blades, two entries for CPs, four
entries for power supplies, and three entries for fans
Brocade DCX-4S directors can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (four port blades, two CPs,
two power supplies, two fans)
Module: Eight entries for port blades, two entries for CPs, four
entries for power supplies, and three entries for fans
Brocade 12000, 24000, and 48000 directors can have the following
hierarchy of physical objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (eight port blades, two CPs,
four power supplies, three fans)
Module: Eight entries for port blades, two entries for CPs, four
entries for power supplies, and three entries for fans
Brocade 3900 switches can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two
power supplies, six fans)
Module: One entry for switch blade, up to two entries for power
supplies, and up to six entries for fans
Brocade 4100 switches can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two
power supplies, three fans)
Module: One entry for switch blade, up to two entries for power
supplies, and up to three entries for fans
Brocade 7500 and 7600 switches can have the following hierarchy of
physical objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two
power supplies, three fans)
Module: One entry for switch blade, up to two entries for power
supplies, and up to three entries for fans
Brocade 8000 switch can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two
power supplies, three fans)
Module: One entry for switch blade, up to two entries for power
supplies, and up to three entries for fans
TABLE 39
Object and OID Access Description