Brocade Fabric OS MIB Reference v7.1.0 (53-1002750-01, March 2013)

Fabric OS MIB Reference 145
53-1002750-01
Switch system group
6
swBeaconAdmStatus
1.3.6.1.4.1.1588.2.1.1.1.1.19
Read-write The desired status of the switch beacon.
Possible values are:
on (1) - The LEDs on the front panel of the switch run
alternately from left to right and right to left. Set the color to
yellow.
off (2) - Set each LED to its regular status, indicating color and
state.
swDiagResult
1.3.6.1.4.1.1588.2.1.1.1.1.20
Read only The result of the power-on startup test (POST) diagnostics.
Possible values are:
sw-ok (1) - The switch is okay.
sw-faulty (2) - The switch has experienced an unknown fault.
sw-embedded-port-fault (3) - The switch has experienced an
embedded port fault.
swNumSensors
1.3.6.1.4.1.1588.2.1.1.1.1.21
Read only The number of sensors inside the switch.
The Brocade DCX value is between 1 and 57 (temperature =50, fan
= 3, power supply = 4). The value might vary depending on the
switch model. For Fabric OS v6.1.0, if no sensor is available, this
variable is assigned the value -1.
swSensorTable
1.3.6.1.4.1.1588.2.1.1.1.1.22
Not
accessible
Table of sensor entries.
Table 46 lists the sensors on the Brocade switches.
The sensors on the switches vary based on the blades. For the
exact count of temperature sensors, refer to Table 47.
swSensorEntry
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1
Not
accessible
An entry of the sensor information.
swSensorIndex
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.1
Read only The index of the sensor.
The values are 1 through the value in swNumSensors
swSensorType
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.2
Read only The type of sensor.
swSensorStatus
1.3.6.1.4.1.1588.2.1.1.1.1.22
.1.3
Read only The current status of the sensor.
Possible values are:
unknown (1)
faulty (2)
below-min (3) - The sensor value is below the minimal
threshold.
nominal (4)
above-max (5) - The sensor value is above the maximum
threshold.
absent (6) - The sensor is missing.
For Temperature, valid values include 3 (below-min), 4 (nominal),
and 5 (above-max).
For Fan, valid values include 3 (below-min), 4 (nominal), and 6
(absent).
For Power Supply, valid values include 2 (faulty), 4 (nominal), and 6
(absent).
TABLE 45
Object and OID Access Description