Brocade Fabric OS MIB Reference v7.1.0 (53-1002750-01, March 2013)

Fabric OS MIB Reference 147
53-1002750-01
Switch system group
6
swBrcdTrapBitMask
1.3.6.1.4.1.1588.2.1.1.1.1.34
Not
accessible
This represents the type of notification by a single bit.
0x01 - Fabric change event
0x02 - Device change event
0x04 - FAPWWN change event
0x08 - FDMI events
swFCPortPrevType
1.3.6.1.4.1.1588.2.1.1.1.1.35
Not
accessible
This represents the port type of a port before it goes online or
offline and it is valid only in swFcPortSCN trap.
Valid values are:
unknown (1)
other (2)
fl-port (3) - public loop
f-port (4) - fabric port
e-port (5) - fabric expansion port
g-port (6) - generic fabric port
ex-port (7)
swDeviceStatus
1.3.6.1.4.1.1588.2.1.1.1.1.36
Not
accessible
This represents the status of the attached device. The status
changes whenever the port or the node goes to online or offline
state.
TABLE 46 Sensors on the various Brocade switches
Platform Temp Fans Power supply swNumSensors /
connUnitNumSensors
Brocade 200E 2 sensors 3 fans 1 PS 6
Brocade 300 3 sensors 3 fans 1 PS 7
Brocade 3014 3 sensors NA NA 3
Brocade 3016 4 sensors NA NA 4
Brocade 3250 4 sensors 3 fans 1 PS 8
Brocade 3850 4 sensors 4 fans 2 PS 10
Brocade 3900 5 sensors 6 fans 2 PS 13
Brocade 4012 2 sensors NA NA 2
Brocade 4016 3 sensor NA NA 3
Brocade 4018 1 sensor NA NA 1
Brocade 4020 2 sensors NA NA 2
Brocade 4024 2 sensors NA NA 2
Brocade 4100 5 sensors 3 fans 2 PS 10
Brocade 4424 3 sensors NA NA 3
Brocade 4900 3 sensors 3 fans 2 PS 18
Brocade 5000 4 sensors 2 fans 2 PS 8
Brocade 5100 4 sensors 2 fans 2 PS 8
Brocade 5300 3 sensors 3 fans 2 PS 8
Brocade 5410 3 sensors NA NA 3
TABLE 45