Brocade Fabric OS MIB Reference v7.1.0 (53-1002750-01, March 2013)

160 Fabric OS MIB Reference
53-1002750-01
Fabric Watch group
6
TABLE 53
Object and OID Access Description
swFwSystem
1.3.6.1.4.1.1588.2.1.1.1.10
Not
accessible
The OID sub-tree for switch Fabric Watch group.
swFwFabricWatchLicense
1.3.6.1.4.1.1588.2.1.1.1.10.1
Read only This OID indicates whether the switch has proper Fabric Watch
license or not.
If the license key is installed on the switch for Fabric Watch, the
return value is swFwLicensed; otherwise, the value is
swFwNotLicensed.
swFwClassAreaTable
1.3.6.1.4.1.1588.2.1.1.1.10.2
Not
accessible
The table of classes and areas.
swFwClassAreaEntry
1.3.6.1.4.1.1588.2.1.1.1.10.2.1
Not
accessible
An entry of the classes and areas.
swFwClassAreaIndex
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
Read only This index represents the Fabric Watch classArea combination.
For the class areas configured in the switch, use the thconfig
--show <class_name> command.
swFwWriteThVals
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.2
Read-write This applies or cancels the configuration value changes.
For a read operation, the return value is always
swFwCancelWrite.
The following custom configuration variables can be modified:
swFwCustUnit
swFwCustTimebase
swFwCustLow
swFwCustHigh
swFwCustBufSize
Changes to these custom configuration variables can be saved
by setting this variable to swFwApplyWrite; they can be removed
by setting this variable to swFwCancelWrite.
swFwDefaultUnit
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.3
Read only A default unit string name, used to identify the unit of measure
for a Fabric Watch classArea combination.
C = environment (class), temperature (area).
RPM = environment (class), fan (area).
swFwDefaultTimebase
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.4
Read only A default polling period for the Fabric Watch classArea
combination.
swFwTbMin = port (class), link loss (area).
swFwTbNone = environment (class), temperature (area).
swFwDefaultLow
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.5
Read only A default low threshold value.
swFwDefaultHigh
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.6
Read only A default high threshold value.
swFwDefaultBufSize
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.7
Read only A default buffer size value.
swFwCustUnit
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.8
Read only A customizable unit string name, used to identify the unit of
measure for a Fabric Watch classArea combination.
C = environment (class), temperature (area).
RPM = environment (class), fan (area).