Brocade Fabric OS MIB Reference v7.1.0 (53-1002750-01, March 2013)

220 Fabric OS MIB Reference
53-1002750-01
Connectivity unit group
9
connUnitPortProtocolCap
1.3.6.1.3.94.1.10.1.20
Read only This is the bit mask that specifies the driver-level protocol capability of
this port.
If this is not applicable, return all bits set to 0.
Return value = 07F
The bits have the following definition.
0 = unknown
1 = Loop
2 = Fabric
4 = SCSI
8 = TCP/IP
16 = VI
32 = FICON
connUnitPortProtocolOp
1.3.6.1.3.94.1.10.1.21
Read only This is the bit mask that specifies the driver level protocols that are
currently operational.
Return value = 07F
If this is not applicable, return all bits set to zero. The bits have the
following definition:
0 = unknown
1 = Loop
2 = Fabric
4 = SCSI
8 = TCP/IP
16 = VI
32 = FICON
connUnitPortNodeWwn
1.3.6.1.3.94.1.10.1.22
Read only The node World Wide Name of the port, if applicable; otherwise, an
empty string.
All ports on HBAs on a host will have the same node WWN. All ports on
the same storage subsystem will have the same node WWN.
This is in IEEE Extended format and the extension contains the internal
port number of each port.
The internal port number is 1 less than the port index. For example, if
the switch has WWN 10:00:00:60:69:10:02:18, then port number 0
and 6 have WWN 20:00:00:60:69:10:02:18 and
20:06:00:60:69:10:02:18, respectively. However, the embedded port
has WWN 10:00:00:60:69:10:02:18, the same as the switch.
The N_Ports on a Brocade Access Gateway are the WWN of the switch
(that is, it is the same as the connUnitId). The F_Ports are the WWN of
the HBA host. If the F_Port is offline, the value of the WWN is zero
(00:00:00:00:00:00:00:00).
connUnitPortHWState
1.3.6.1.3.94.1.10.1.23
Read only The state of the port as detected by the hardware.
Possible values are:
unknown (1)
failed (2) Port failed diagnostics (port_flt_state).
bypassed (3) FCAL bypass, loop only (not used).
active (4) Connected to a device (light and sync are present).
loopback (5) Port in ext loopback (loopback state).
txfault (6) Transmitter fault (bad GBIC).
noMedia (7) Media not installed (GBIC removed).
linkDown (8) Waiting for activity—rx sync (light with no sync).
TABLE 75