HP B-series Network Advisor Enterprise, Professional Plus, and Professional 11.1.5 Release Notes (5697-2464, January 2013)

Table 12 HP Network Advisor 11.1.5 closed defects (continued)
SolutionClosed fixes summary
Fixed in Network Advisor 11.1.5.Unable to launch the Discovery Dialog in a single monitor when previously
launched in a dual monitor setup.
Fixed in Network Advisor 11.1.5.The HP-branded SCOM package cannot be installed.
Fixed in Network Advisor 11.1.5.An event action is not triggered for the corresponding port when an SNMP
trap is generated for FC Port Level events.
Fixed in Network Advisor 11.1.5.Email notification settings are not persistent.
Fixed in Network Advisor 11.1.5.The Description field for User Action Events is empty in the Event Custom
report.
Workaround prior to upgrade: Create an
offline zone database in both fabrics and
activate the zone configuration.
Fixed in Network Advisor 11.1.5.
When performing zoning merge operations using Network Advisor, zone
members become out-of-order between the application and the switch.
Fixed in Network Advisor 11.1.5.Network Advisor clients are unable to login to using LDAP AD services.
Fixed in Network Advisor 11.1.5.Authentication to Network Advisor does not work when the Display Name
and user login name are different for an account on the LDAP server.
Fixed in Network Advisor 11.1.5.Users are unable to add some storage devices shown under the storage
group topology view to storage port mapping.
Fixed in Network Advisor 11.1.5.It takes a long time to log in to the Network Advisor client and switch
between views.
Fixed in Network Advisor 11.1.5.In the zoning dialog, the Host group cannot be expanded by clicking on
the + icon, after the tree is sorted.
Fixed in Network Advisor 11.1.5.Email notification is not received for a switch in Network Advisor when a
port faulted due to SFP validation failure.
Fixed in Network Advisor 11.1.5.When a user attempts to replicate SNMP settings from a switch/AG to
another AG, the dialog becomes unresponsive and the settings are not
replicated.
Fixed in Network Advisor 11.1.5.The Server Management Console always creates its lock file, smc.lock,
in the root directory instead of the directory where Network Advisor is
installed.
Workaround prior to upgrade: Move ports
one slot at a time.
Fixed in Network Advisor 11.1.5.
The Network Advisor client hangs during logical switch configuration if
ports are moved from multiple FID's belonging to different slots.
Fixed in Network Advisor 11.1.5.The Network Advisor client hangs when the levels in the Product Tree are
shifted.
Fixed in Network Advisor 11.1.5.The Network Advisor client hangs when the levels in the Product Tree are
shifted due to RADIUS user login failure.
Effective date
January 2013
24