Fabric OS Administrator's Guide, 7.1.0 (53-1002745-02, March 2013)

614 Fabric OS Administrator’s Guide
53-1002745-02
Port Indexing
A
Example of port indexing on an FS8-18 blade on a DCX 8510-8 Backbone
This example shows the truncated switchShow output for an FS8-18 encryption blade on the
Brocade DCX 8510-8 Backbone. The assignment of port index numbers to PIDs will vary depending
on blade type, platform type, and slot number.
switch:FID128:admin> switchshow -slot 2
switchName: myswitch
(output truncated)
Slot Blade Type ID Model Name Status
--------------------------------------------------
2 AP BLADE 43 FS8-18 ENABLED
Index Slot Port Address Media Speed State Proto
==================================================================
16 2 0 501000 -- N8 No_Module FC
17 2 1 501100 -- N8 No_Module FC
18 2 2 501200 -- N8 No_Module FC
19 2 3 501300 -- N8 No_Module FC
20 2 4 501400 -- N8 No_Module FC
(output truncated)
31 2 15 501f00 id N4 No_Light FC