Cisco Nexus 5000 Series Switch Fabric Manager Software Configuration Guide, NX-OS 4.0 (OL-16598-01, June 2008)
Send comments to nx5000-docfeedback@cisco.com
14-6
Nexus 5000 Series Switch Fabric Manager Software Configuration Guide
OL-16598-01
Chapter 14 Configuring SAN Port Channels
Configuring SAN Port Channels
Figure 14-6 Misconfigured Configurations
This section shows how to configure and modify SAN port channels and includes the following topics:
• SAN Port Channel Configuration Guidelines, page 14-6
• Configuring SAN Port Channels, page 14-7
• About SAN Port Channel Modes, page 14-10
• About SAN Port Channel Deletion, page 14-11
• Deleting SAN Port Channels, page 14-11
SAN Port Channel Configuration Guidelines
Before configuring a SAN port channel, consider the following guidelines:
• Configure the SAN port channel using Fibre Channel ports from both expansion modules to provide
increased availability (if one of the expansion modules failed).
• Ensure that one SAN port channel is not connected to different sets of switches. SAN port channels
require point-to-point connections between the same set of switches.
If you misconfigure SAN port channels, you may receive a misconfiguration message. If you receive this
message, the port channel’s physical links are disabled because an error has been detected.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Switch A Switch B Switch A Switch B
Channel Group 10 Channel Group 20 Channel Group 10 Channel Group 20
1
2
3
4
1
2
3
4
Channel Group 10 Channel Group 20
187236
Switch A
Switch B
Switch C
X
X
X
X
X
X