Cisco Nexus 5000 Series Switch Fabric Manager Software Configuration Guide, NX-OS 4.0 (OL-16598-01, June 2008)

Send comments to nx5000-docfeedback@cisco.com
14-6
Nexus 5000 Series Switch Fabric Manager Software Configuration Guide
OL-16598-01
Chapter 14 Configuring SAN Port Channels
Configuring SAN Port Channels
Figure 14-6 Misconfigured Configurations
This section shows how to configure and modify SAN port channels and includes the following topics:
SAN Port Channel Configuration Guidelines, page 14-6
Configuring SAN Port Channels, page 14-7
About SAN Port Channel Modes, page 14-10
About SAN Port Channel Deletion, page 14-11
Deleting SAN Port Channels, page 14-11
SAN Port Channel Configuration Guidelines
Before configuring a SAN port channel, consider the following guidelines:
Configure the SAN port channel using Fibre Channel ports from both expansion modules to provide
increased availability (if one of the expansion modules failed).
Ensure that one SAN port channel is not connected to different sets of switches. SAN port channels
require point-to-point connections between the same set of switches.
If you misconfigure SAN port channels, you may receive a misconfiguration message. If you receive this
message, the port channel’s physical links are disabled because an error has been detected.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Switch A Switch B Switch A Switch B
Channel Group 10 Channel Group 20 Channel Group 10 Channel Group 20
1
2
3
4
1
2
3
4
Channel Group 10 Channel Group 20
187236
Switch A
Switch B
Switch C
X
X
X
X
X
X