Cisco Nexus 5000 Series Switch Fabric Manager Software Configuration Guide, NX-OS 4.0 (OL-16598-01, June 2008)

Send comments to nx5000-docfeedback@cisco.com
16-13
Nexus 5000 Series Switch Fabric Manager Software Configuration Guide
OL-16598-01
Chapter 16 Configuring and Managing Zones
Zone Sets
About FC Alias Creation, page 16-17
Creating FC Aliases, page 16-17
Adding Members to Aliases, page 16-18
Converting Zone Members to pWWN-Based Members, page 16-20
Zone Enforcement, page 16-21
About Zone Set Creation
In Figure 16-13, two separate sets are created, each with its own membership hierarchy and zone
members.
Figure 16-13 Hierarchy of Zone Sets, Zones, and Zone Members
Zones provide a method for specifying access control, while zone sets are a grouping of zones to enforce
access control in the fabric. Either zone set A or zone set B can be activated (but not together).
Tip Zone sets are configured with the names of the member zones and the VSAN (if the zone set is in a
configured VSAN).
Activating a Zone Set
Changes to a zone set do not take effect in a full zone set until you activate it.
To activate an existing zone set using Fabric Manager, perform this task:
Step 1 Choose Zone > Edit Local Full Zone Database.
You see the Select VSAN dialog box.
Zone 3
H2, S2
Zone 2
H3, S2
Zone 1
H1, H3, S1
Zone set A Zone set B
H1 H2 H3
S1 S2
79537