Cisco Nexus 5000 Series Switch Fabric Manager Software Configuration Guide, NX-OS 4.0 (OL-16598-01, June 2008)

Send comments to nx5000-docfeedback@cisco.com
22-11
Nexus 5000 Series Switch Fabric Manager Software Configuration Guide
OL-16598-01
Chapter 22 Advanced Features and Concepts
Switch Interoperability
Verifying Interoperating Status
This section highlights the steps used to verify if the fabric is up and running in interoperability mode.
To verify the interoperability status of the Cisco Nexus 5000 Series switch using Fabric Manager,
perform this task:
Step 1 Choose Switches in the Physical Attributes pane and check the release number in the Information pane
to verify the Cisco SAN-OS release.
Step 2 In the Physical Attributes pane, expand Switches > Interfaces, and then choose FC Physical to verify
the interface modes for each switch.
Step 3 Expand Fabricxx in the Logical Domains pane, and then choose All VSANs to verify the interop mode
for all VSANs.
Step 4 Expand Fabricxx > All VSANs, and then choose Domain Manager to verify the domain IDs, local, and
principal sWWNs for all VSANs (see Figure 22-6).
Figure 22-6 Domain Manager Information
Step 5
Using Device Manager, choose FC > Name Server to verify the name server information.
You see the Name Server dialog box as shown in Figure 22-7.
Figure 22-7 Name Server Dialog Box
Step 6
Click Close to close the dialog box.