HP StorageWorks C-Series Fabric Switches for NX-0S 4.1(3a) Release Notes (AA-RWEHS-TE, March 2009)

16 MDS Multilayer Director & Multilayer Fabric Switches Release Notes
5. Enter the following command to enable the VSAN(s) that contain the Continuous Access
EVA and/or DRM fabric to src-dst-id loadbalancing:
switch(config-vsan-db)# vsan <1-4094> loadbalancing src-dst-id
switch(config-vsan-db)# exit
switch(config)# exit
6. Verify that src-dst-id is enabled for the desired VSAN by entering the following
command:
switch# show vsan <1-4094>
In the following example, VSAN 1 loadbalancing is set to src-id/dst-id
switch# show vsan 1
vsan 1 information
name: vsan1 state: active
interoperability mode: default
loadbalancing: src-id/dst-id
operational state: up
7. Type the following to copy the running configuration into the startup configuration:
switch# copy running-config startup-config
Refer to the Cisco MDS 9000 Family Fabric Manager Switch Configuration Guide to set
src-dst-id using Device/Fabric Manager.
Note: The running configuration overwrites the startup configuration.
C-SERIES MDS 9134 FABRIC SWITCH
The MDS 9134 switch has a base 34-port chassis to accommodate up to 32 full rate 4-Gbps and 2
10-Gbps fibre channel ports. Four configurations are available:
24 4-Gbps active ports with optional 8-port 4-Gbps and 2-port 10-Gbps software
expansion licenses
32 4-Gbps active ports with an optional 2-port 10-Gbps software expansion license
24 4-Gbps and 2 10-Gbps active ports; a 48-port stackable solution is available with the
purchase of two of these products.
32 4-Gbps and 2 10-Gbps active ports; a 64-port stable solution is available with the
purchase of two of these products.
C-SERIES MDS 9124 FABRIC SWITCH
The MDS 9124 switches have fixed configurations with 8, 16, and 24 full rate 4-Gbps fibre
channel ports. The 8 and 16 port switches can be upgraded in 8 port increments with a software
expansion license.