Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

2-126 Fabric OS Command Reference Manual
Publication Number: 53-1000240-01
diagModeShow
2
Note: Enter commands in lowercase only; mixed case is for readability.
diagModeShow
Displays diagnostic mode configuration.
Synopsis diagmodeshow
Description Use this command to display the current settings for several diagnostic configuration parameters. This
command is most often used by burn-in scripts to display a summary of the configuration settings that
were in effect when the script was run.
N
ote
Any automated use of this command should rely only on the names of the specific variables, not on their
exact positions in the output. Earlier versions of this command listed diag.mode.burnin.nExec instead of
Burnin nExec and diag.mode.burnin.nExec instead of Burnin passnum.
You can issue this command on the FR4-18i blade in a SilkWorm chassis; however, the command is not
supported by the SilkWorm platform and does not effect any other feature operations. This availability
is offered to maintain consistency across a mixed-blade environment.
N
ote
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands none
Examples To display the diagnostic mode:
See Also burninLevel, setEsdMode, setGbicMode, setSplbMode
switch:admin> diagmodeshow
diag.mode* parameters saved in flash:
diag.mode.burnin = 0
diag.mode.burnin.level = 0
diag.mode.burnin.firstPowerUp = Thu Feb 28 01:36:12 2002
diag.mode.esd = 0
diag.mode.gbic = 0
diag.mode.splb = 0
diag.mode.lab = 0
diag.mode.mfg = 0
diag.mode.bplb = 0
diag.ports = TEST (type=INDEX, sz=512): 100.
Burnin passnum = 1
Burnin nExec = 0
Silkworm Mode = OFF
Disable Modes Print = OFF