Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

Fabric OS Command Reference Manual 2-135
Publication Number: 53-1000240-01
diagStopBurnin
2
Note: Enter commands in lowercase only; mixed case is for readability.
diagStopBurnin
Terminates a blade burn-in run.
Synopsis diagstopburnin [--slot number]
Description Use this command to determine which PID is running burn-in on a blade and terminate that activity. The
burn-in script handles the logging cleanup.
This command does not require a reboot to take effect.
Operands This command has the following operands:
--slot number Specify the slot to stop burn-in. If no slot is specified, this command executes on
all slots in the logical switch. This operand is optional.
Examples To stop burn-in mode on a switch:
See Also diagSetBurnin
switch:admin> diagstopburnin --slot 1
No burn-in script active on slot 1
1 burninErrShow output:
0x1eea (fabos): Dec 19 14:42:18
Switch: 0, Error DIAG-MANUAL1, 1, " 1 Starting switchess ...
Err# 0140042 0100:101:000:001:24:37:
0xc84 (fabos): Dec 20 08:57:27
Switch: 0, Error DIAG-MANUAL1, 1, " 1 switchess: ABORT ...
Err# 0140042 0100:101:000:000:25:41:
0x1b61 (fabos): Feb 07 19:02:28
Switch: 0, Error DIAG-MANUAL1, 1, " 1 Starting switchess ...
Err# 0140042 0100:101:000:001:26:39:
0x47ff (fabos): Feb 07 21:45:36
Switch: 0, Error DIAG-MANUAL1, 1, " 1 switchess: ABORT ...
Err# 0140042 0100:101:000:002:26:41:1N