Brocade Fabric OS Command Reference Manual (53-1000240-01, November 2006)

Fabric OS Command Reference Manual 2-197
Publication Number: 53-1000240-01
fcrPathTest
2
Note: Enter commands in lowercase only; mixed case is for readability.
7. RANDOM 0x25, 0x7f, 0x6e, 0x9a, ...
N
ote
This command is supported only on SilkWorm FR4-18i blades and SilkWorm 7500 platforms.
Operands This command has the following operands:
--slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and
operates on fixed-port-count products.
-unit number Specifies the FC Router FPGA to test. By default, all FC Router FPGA in the
specified slotnumber are used. Valid number values include:
0 FC Router FPGA 0
1 FC Router FPGA 1
2 All FC Router FPGA
-path mode Specifies the loopback point for the test. By default, fcrPathTest uses central
ASIC loopback. Valid mode values include:
1 Central ASIC loopback
2 FC Router FPGA Serdes loopback
3 FC Router FPGA internal loopback
-nmegs count Specifies the number of frames to send. The test progresses until the specified
number of frames are transmitted on each port. The default value is 10.
Examples To test slot 2 with FC Router FPGA Serdes loopback sending 10 frames:
Diagnostics When a failure is detected, the test might report one or more of the following:
DATA
•ERRSTAT
•INIT
•PORTDIED
STATS
•TIMEOUT
•XMIT
See Also fcrChipTest, miniCycle, portLoopbackTest
switch:admin> fcrpathtest --slot 2 -path 2 -nmegs 10
Running fcrpathtest ..............
Test Complete: fcrpathtest Pass 10 of 10
Duration 0 hr, 0 min & 18 sec (0:0:18:942).
passed.